• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: ARROW INTERNATIONAL INC. ARROW CVC SET: 2-LUMEN 8 FR X 20 CM; CATHETER,INTRAVASCULAR,THERAP

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

ARROW INTERNATIONAL INC. ARROW CVC SET: 2-LUMEN 8 FR X 20 CM; CATHETER,INTRAVASCULAR,THERAP Back to Search Results
Catalog Number CS-25802-E
Device Problems Kinked (1339); Difficult To Position (1467)
Patient Problems No Known Impact Or Consequence To Patient (2692); No Information (3190)
Event Date 09/21/2017
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Additional information: it is unknown if the device sample is available for evaluation.
 
Event Description
The customer reports the doctor found it difficult to pass through the swg (spring wire guide), the insertion failed.The swg was checked and was found kinked.The device was replaced.A delay in treatment was reported.
 
Manufacturer Narrative
(b)(4).The customer returned a guide wire assembly for evaluation.The guide wire was returned within the advancer tube.The advancer assembly was returned with the advancer tube partially disassembled.The guide wire was observed to have several kinks towards the distal end of the body and at the center of the body.The distal j-bend was kinked and deformed but intact.Microscopic examination confirmed the kinks in the guide wire body.Offset coils were observed at the kink closest to the distal tip.Both welds were present and were observed to be full and spherical.The guide wire was kinked 8, 25, 201 and 242mm from the distal tip.Offset coils were observed at the kink 8mm from the distal tip.The overall length and outer diameter of the guide wire were measured and were found to be within specification.The guide wire was advanced through a lab inventory ars and a lab inventory 18ga introducer needle to functionally test the guide wire.The guide wire passed through both components with minimal resistance.A manual tug test confirmed that b oth the distal and proximal welds were intact.A device history record review was performed on the guide wire and no relevant manufacturing issues were identified.The instructions-for-use (ifu) provided with this product describes suggested techniques to minimize the likelihood of guide wire damage during use.The ifu cautions that if resistance is encountered when attempting to remove the spring-wire guide after catheter placement, the spring-wire may be kinked about the tip of the catheter within the vessel which may result in undue force being applied resulting in spring-wire guide breakage.If resistance is encountered, withdraw the catheter relative to the spring-wire guide about 2-3cm and attempt to remove the spring-wire guide.If resistance is again encountered, remove the spring-wire guide and catheter simultaneously.The report that the guide wire kinked during use was confirmed through examination of the returned sample.The guide wire was kinked in several locations towards the distal tip.The returned guide wire met all relevant dimensional requirements and a device history record review did not identify any manufacturing related issues.Based on the condition of the guide wire and the report that the damage was observed during use, it was determined that operational context caused or contributed to this event.Teleflex will continue to monitor and trend for reports of this nature.
 
Event Description
The customer reports the doctor found it difficult to pass through the swg (spring wire guide), the insertion failed.The swg was checked and was found kinked.The device was replaced.A delay in treatment was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARROW CVC SET: 2-LUMEN 8 FR X 20 CM
Type of Device
CATHETER,INTRAVASCULAR,THERAP
Manufacturer (Section D)
ARROW INTERNATIONAL INC.
reading PA
Manufacturer (Section G)
ARROW INTERNATIONAL CR, A.S.
jamska 2359/47
zdar nad sazavou 591 0 1
EZ   591 01
Manufacturer Contact
katharine tarpley
3015 carrington mill blvd
morrisville, NC 27560
9194334854
MDR Report Key7177341
MDR Text Key96823775
Report Number3006425876-2018-00048
Device Sequence Number1
Product Code FOZ
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
K900263
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Other Health Care Professional
Type of Report Initial,Followup
Report Date 12/26/2017
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date07/31/2018
Device Catalogue NumberCS-25802-E
Device Lot Number71F16J2034
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/15/2018
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 12/26/2017
Initial Date FDA Received01/09/2018
Supplement Dates Manufacturer Received02/13/2018
Supplement Dates FDA Received02/13/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/26/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-