MAUDE Adverse Event Report: CORDIS CASHEL 466P306X; CATHETER, INTRAVASCULAR, DIAGNOSTIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

CORDIS CASHEL 466P306X; CATHETER, INTRAVASCULAR, DIAGNOSTIC Back to Search Results
Catalog Number 466P306X
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Embolus (1830); Occlusion (1984); Thrombosis (2100)
Event Date 10/04/2016
Event Type  Injury  
Manufacturer Narrative
As reported, the patient underwent placement of a trapease vena cava filter.The filter subsequently malfunctioned and caused injury and damages to the patient, including, but no limited to, blood clots and deep vein thrombosis (dvt).As a direct and proximate result of these malfunctions, the patient suffered life-threatening injuries and damages, and required extensive medical care and treatment.As a further proximate result, the patient has suffered and will continue to suffer significant medical expenses, pain and suffering, and other damages.The product was not returned for analysis.A review of the device history record revealed no anomalies during the manufacturing and inspection processes that can be associated with the reported complaint.The inferior vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pulmonary embolism where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pulmonary embolism where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.The development of blood clots do not represent a device malfunction.Blood clots that develop in the veins of the leg or pelvis, may be related to a condition called deep vein thrombosis (dvt).Large thrombus within the vena cava or lower extremities may impede perfusion and cause venous insufficiency.Clinical factors that may have influenced the event include patient, pharmacological, lesion characteristics or other comorbidities.Based on the minimal information provided, it is not possible to draw a clinical conclusion or determine a root cause for the reported event.Given the limited information available for review at this time, there is nothing to suggest that the reported event is related to the design, manufacturing process or implantation of the device; therefore no corrective action will be taken.Should additional information become available, the file will be updated accordingly.
 
Event Description
As reported by the legal brief, the patient underwent placement of defendants' trapease vena cava filter.The filter subsequently malfunctioned and caused injury and damages to the patient, including, but no limited to, blood clots and deep vein thrombosis (dvt).As a direct and proximate result of these malfunctions, the patient suffered life-threatening injuries and damages, and required extensive medical care and treatment.As a further proximate result, the patient has suffered and will continue to suffer significant medical expenses, pain and suffering, and other damages.
 
Manufacturer Narrative
After further review of additional information received the following sections have been updated accordingly.As reported, the patient underwent placement of the trapease inferior vena cava (ivc) filter.The indication for filter placement is not available.The filter subsequently malfunctioned and caused injury and damages to the patient, including, but no limited to, blood clots and deep vein thrombosis (dvt).Per the patient profile from (ppf), the patient became aware of the events approximately one year and nine months post implantation of the filter.The patient reports blood clots, clotting, and/or occlusion of the ivc.The filter remains implanted; thus, unavailable for analysis.The product was not returned for analysis and the sterile lot number has not been provided; therefore, no device analysis nor device history record review could be performed.The trapease vena cava filter is indicated for use in the prevention of recurrent pulmonary embolism (pe) via percutaneous placement in the vena cava for patients in which anticoagulants are contraindicated, anticoagulant therapy for thromboembolic disease has failed, emergency treatment following massive pulmonary embolism where anticipated benefits of conventional therapy are reduced or for chronic, recurrent pulmonary embolism where anticoagulant therapy has failed, or is contraindicated.The purpose of a vena cava filter is to catch thrombus from the lower extremities as it travels along normal blood flow patterns up towards the heart.Blood clots, dvt and occlusive thrombosis within the filter and vasculature do not represent a device malfunction.Clinical factors that may have influenced the event include patient, pharmacological and lesion characteristics.Without procedural films or images for review the reported event(s) could not be confirmed.Given the limited information available for review at this time, there is nothing to suggest that the reported events are related to the design and manufacturing process of the device; therefore, no corrective action will be taken.Should additional information become available, the file will be updated accordingly.
 
Manufacturer Narrative
According to the information received in the patient profile from (ppf), the patient became aware of the alleged events approximately on or about one year and nine months post implantation of the inferior vena cava (ivc).The patient reports to suffer from blood clots, clotting, and/or occlusion of the ivc.Additional information is pending and will be submitted within 30 days upon receipt.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
466P306X
Type of Device
CATHETER, INTRAVASCULAR, DIAGNOSTIC
Manufacturer (Section D)
CORDIS CASHEL
cahir road
cashel, co. tipperary
EI 
MDR Report Key7369326
MDR Text Key103412973
Report Number1016427-2018-01278
Device Sequence Number1
Product Code DQO
Combination Product (y/n)N
PMA/PMN Number
K020316
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Type of Report Initial,Followup,Followup
Report Date 06/26/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number466P306X
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 03/09/2018
Initial Date FDA Received03/26/2018
Supplement Dates Manufacturer Received05/04/2018
06/03/2018
Supplement Dates FDA Received06/01/2018
06/26/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Life Threatening; Disability;
Patient Age88 YR
-
-