Model Number N/A
Device Problem Appropriate Term/Code Not Available (3191)
Patient Problem No Information (3190)
Event Date 02/26/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The complaint device has been returned, but the device investigation has not yet been completed.Once the evaluation is completed, a supplemental medwatch will be submitted.
 
Event Description
It was reported that the pin driver sheared off the head of the pin and it got stuck.
 
Manufacturer Narrative
If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event Description
The tibial guide bottom hole did not allow a pin to penetrate it.
 
Manufacturer Narrative
(b)(4).(udi): (b)(4).Concomitant medical product: catalog #: 00590102000, headless trocar drill pin, lot # 63752272.Reported event was considered confirmed as there were burrs in the hold of the returned tibial cut guide.Device history record was reviewed and no discrepancies relevant to the reported event were found.Root cause was unable to be determined as the reason for the burrs cannot be identified.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Event Description
No further event information available at the time of this report.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PERSONA TIBIAL CUT GUIDE
Type of Device
KNEE INSTRUMENT
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key7378534
MDR Text Key103948817
Report Number0001825034-2018-02219
Device Sequence Number1
Product Code HTJ
Combination Product (y/n)N
PMA/PMN Number
PEXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,health profession
Type of Report Initial,Followup,Followup
Report Date 03/20/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number42539905185
Device Lot Number63865999
Other Device ID NumberN/A
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer03/02/2018
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 02/28/2018
Initial Date FDA Received03/28/2018
Supplement Dates Manufacturer Received03/08/2018
03/14/2019
Supplement Dates FDA Received04/04/2018
03/20/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Age37 YR
Patient Weight140
-
-