Device Problem Use of Device Problem (1670)
Patient Problem Partial thickness (Second Degree) Burn (2694)
Event Type  Injury  
Manufacturer Narrative
General use patient gown.The product code listed is not correct.This device is not classified as a medical device.This is a general use patient gown.The initial reporter identified this as an examination gown incorrectly.Model #749d6425, lot #cdc010313880.Other - the information supplied on the gown's use does not meet the fda criteria for a reportable event.The patient gown was not directly implicated in the patient burn/blisters, i.E., gown had no contact with affected area.This was confirmed during follow-up discussions with the (6) hosp.On 2/14/2018 standard textile's vice president of quality, spoke directly with (b)(6), risk management specialist, at (b)(6) hospital.She confirmed that the gown in question came from a completed trial from the (b)(6) burn unit and that the gowns were provided, not purchased.When the trial was completed, the gowns were not returned.Ms.(b)(6) believes that these gowns were put into their regular laundry and circulated with the other examination gowns.Subsequently this patient gown was used on the mri patient that had this medical event occur.As this gown has snaps/metal closures on the top/neck, the mri instruction for use preclude metal from being used during the procedure.Ms.Owens did confirm that metal snaps would not be appropriate for an mri procedure.Important note: the snaps on the gown were not in close proximity to the patient burn/blisters and the upper body areas in contact with the snaps were not associated with the burns or blistering.No adverse effects were observed due to the use of this gown even though gowns with metal snaps should not be used in mri's.Our conclusion is that the patient gown was not involved with the burn/blistering reported by the patient.- attachment: (b)(4).
 
Event Description
Hospital indicated that a patient with right leg edema was undergoing an mri and indicated that she felt something during the scan.The scan was stopped and there were two welts on the insides of her thighs.The patient wanted to proceed with the scan.After the scan was complete, blisters appeared in the area of the welts.The gown and robe she was wearing was not touching the area where the blisters arose.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DERMATHERAPY
Type of Device
EXAMINATION, GOWN
Manufacturer Contact
bradley bushman
one knollcrest drive
cincinnati, OH 45237
5137619255
MDR Report Key7425294
MDR Text Key105313114
Report Number0001527185-2018-00001
Device Sequence Number1
Product Code FME
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
NONE
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Reporter Occupation Other
Type of Report Initial
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received04/12/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator No Information
Is the Reporter a Health Professional? No
Was the Report Sent to FDA? No
Date Manufacturer Received02/12/2018
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured11/12/2016
Is the Device Single Use? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-