• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: BAXTER HEALTHCARE - CALI PLEXITRON SOLUTION ADMINISTRATION SETS; SET, ADMINISTRATION, INTRAVASCULAR

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BAXTER HEALTHCARE - CALI PLEXITRON SOLUTION ADMINISTRATION SETS; SET, ADMINISTRATION, INTRAVASCULAR Back to Search Results
Catalog Number MRC0001MP
Device Problem Hole In Material (1293)
Patient Problem No Patient Involvement (2645)
Event Type  malfunction  
Manufacturer Narrative
The device was received and evaluation is in progress.Should additional relevant information become available, a supplemental report will be submitted.
 
Event Description
It was reported a plexitron solution administration set leaked during priming.A hole was observed in the injection site of the y side.There was no patient involvement.No additional information is available.
 
Manufacturer Narrative
The device was received for evaluation.A visual inspection was performed and ripped y-site tubing was observed.The reported condition was verified.The cause of the reported condition was an assembly issue due to excess solvent.A nonconformance has been opened to address this issue.A batch review was conducted and there were no deviations found related to this reported condition during the manufacture of this lot.Should additional relevant information become available, a supplemental report will be submitted.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
PLEXITRON SOLUTION ADMINISTRATION SETS
Type of Device
SET, ADMINISTRATION, INTRAVASCULAR
Manufacturer (Section D)
BAXTER HEALTHCARE - CALI
cali
Manufacturer (Section G)
BAXTER HEALTHCARE - CALI
calle 36 no. 2c-22,
apartado aero 2446
cali
CO  
Manufacturer Contact
25212 w. illinois route 120
round lake, IL 60073
2242702068
MDR Report Key7446796
MDR Text Key106040557
Report Number1416980-2018-02280
Device Sequence Number1
Product Code FPA
UDI-Device Identifier07707141305553
UDI-Public(01)07707141305553
Combination Product (y/n)N
Reporter Country CodeCO
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Reporter Occupation Pharmacist
Type of Report Initial,Followup
Report Date 05/23/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date12/31/2022
Device Catalogue NumberMRC0001MP
Device Lot NumberSE17LO9
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer04/09/2018
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 03/26/2018
Initial Date FDA Received04/20/2018
Supplement Dates Manufacturer Received05/09/2018
Supplement Dates FDA Received05/23/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured12/26/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-