Model Number 1457Q/86
Device Problems Difficult to Insert (1316); Difficult to Remove (1528)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 05/21/2018
Event Type  malfunction  
Event Description
It was reported during a procedure, the stylet could not be inserted into the lead.It was also noted the physician had a difficulty to remove the stylet.The lead was removed and a new lead was implanted.No further information is available at this time.
 
Manufacturer Narrative
The reported event of stylet could not be removed was confirmed.As received, a complete lead was returned in one piece with the stylet stuck inside the lead.The cause of reported event was isolated to bunching of the stripped stylet, ptfe coating and inner coil.Abbott is continuing to monitor this issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
QUARTET LEAD DOUBLE BEND, 86 CM
Type of Device
PERMANENT PACEMAKER ELECTRODE
Manufacturer (Section D)
ST. JUDE MEDICAL, INC.(CRM-SUNNYVALE)
645 almanor avenue
sunnyvale CA 94085
Manufacturer (Section G)
ST. JUDE MEDICAL, INC.(CRM-SUNNYVALE)
645 almanor avenue
sunnyvale CA 94085
Manufacturer Contact
robert greenleaf
15900 valley view court
sylmar, CA 91342
8184932577
MDR Report Key7630077
MDR Text Key112049150
Report Number2938836-2018-08120
Device Sequence Number1
Product Code OJX
UDI-Device Identifier05414734510189
UDI-Public05414734510189
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P030054
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Reporter Occupation Physician
Type of Report Initial,Followup
Report Date 07/11/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date08/31/2020
Device Model Number1457Q/86
Device Lot NumberA000045590
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer05/29/2018
Is the Reporter a Health Professional? Yes
Was the Report Sent to FDA? No
Initial Date Manufacturer Received 05/29/2018
Initial Date FDA Received06/22/2018
Supplement Dates Manufacturer Received07/10/2018
Supplement Dates FDA Received07/11/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured09/15/2017
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-