Model Number 2AF284
Device Problem Material Deformation (2976)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 06/07/2018
Event Type  malfunction  
Manufacturer Narrative
Product event summary: the data files and balloon catheter, 2af284 with lot number 91558 were returned and analyzed.The data files showed at least 6 injections were performed with the returned balloon catheter on the date of the event.The data files confirmed system notice (b)(4) unrelated to the reported issue in two injections on the date of the event.Visual inspection of the balloon catheter showed the device was intact with no apparent issues.The catheter passed the performance test, but inflation showed a kink on the guide wire lumen under the balloon segment.Dissection showed a guide wire lumen kink at 0.93 inches from the tip inside the balloons.In conclusion, the reported issue was confirmed through testing and the balloon catheter failed the returned product inspection due to the guide wire lumen kink.If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that during a cryo ablation procedure, during setup while the balloon catheter push button was maneuvered, and the shaft was kinked.The balloon catheter was replaced.The case was completed with cryo.No patient complications have been reported as a result of this event.The balloon catheter subsequently tested out of specification per the manufacturer's investigation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARCTIC FRONT ADVANCE CARDIAC CRYOABLATION CATHETER
Type of Device
PERCUTANEOUS CATHETER INTENDED FOR TREATMENT OF ATRIAL FIBRILLATION
Manufacturer (Section D)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA  H9R 5Z8
Manufacturer (Section G)
MEDTRONIC CRYOCATH LP
9000 autoroute transcanadienne
pointe-claire,qc H9R 5 Z8
CA   H9R 5Z8
Manufacturer Contact
anne schilling
8200 coral sea st ne
mounds view, MN 55112
7635052036
MDR Report Key7868641
MDR Text Key120103423
Report Number3002648230-2018-00646
Device Sequence Number1
Product Code OAE
UDI-Device Identifier00643169753693
UDI-Public00643169753693
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P100010/S015
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 09/12/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date04/30/2019
Device Model Number2AF284
Device Catalogue Number2AF284
Device Lot Number91558
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer06/11/2018
Initial Date Manufacturer Received 08/17/2018
Initial Date FDA Received09/12/2018
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured04/30/2018
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
-
-