Catalog Number PXSLIMLAN135STR
Device Problems Device Handling Problem (3265); Device Fell (4014)
Patient Problem No Patient Involvement (2645)
Event Date 09/28/2018
Event Type  malfunction  
Manufacturer Narrative
This device is available for return.A follow up mdr will be submitted upon completion of the device investigation.
 
Event Description
The patient was undergoing a coil embolization procedure.During the procedure, the hospital staff accidentally dropped the lantern delivery microcatheter (lantern) on the ground; therefore, the lantern was not used in the procedure.The procedure was completed using a non-penumbra microcatheter.
 
Manufacturer Narrative
Please note that the device associated with this complaint was expected to be returned; however, additional information received from the penumbra sales representative indicated that the device was disposed of and is no longer available for return.Therefore, without the return of the device, the root cause of the problem cannot be determined.The manufacturing records for this lot were reviewed and did not reveal any outstanding discrepancies, design, or quality concerns.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LANTERN DELIVERY MICROCATHETER
Type of Device
DQY
Manufacturer (Section D)
PENUMBRA, INC.
one penumbra place
alameda CA 94502
MDR Report Key7997113
MDR Text Key124973617
Report Number3005168196-2018-02104
Device Sequence Number1
Product Code DQY
UDI-Device Identifier00814548016641
UDI-Public00814548016641
Combination Product (y/n)Y
PMA/PMN Number
K152840
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 01/01/2005,09/28/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date05/08/2021
Device Catalogue NumberPXSLIMLAN135STR
Device Lot NumberF83325
Was Device Available for Evaluation? No
Was the Report Sent to FDA? Yes
Date Report Sent to FDA01/01/2005
Date Report to Manufacturer01/10/2005
Initial Date Manufacturer Received 09/28/2018
Initial Date FDA Received10/23/2018
Supplement Dates Manufacturer Received12/04/2018
Supplement Dates FDA Received01/03/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-