Catalog Number 0684-00-0475
Device Problem Suction Problem (2170)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 10/19/2018
Event Type  malfunction  
Manufacturer Narrative
The device has not been returned to the manufacturer so we are unable to complete an evaluation.If provided we will send a supplemental report with our additional findings.(b)(4).
 
Event Description
It was reported that after insertion of the intra-aortic balloon (iab) the physician could not aspirate blood from the inner lumen.The iab was replaced.There was no reported injury to the patient.
 
Manufacturer Narrative
The product was returned with the membrane loosely folded and blood on the exterior of the catheter.The one-way valve was also returned.The technician attempted to flush/aspirate the inner lumen and was unable to do so.The technician then attempted to insert a 0.025¿ laboratory guide wire through the inner lumen of the returned iab and found that the inner lumen was occluded.The technician was unable to clear the occlusion, however evidence of dried blood was observed at the tip of the guide wire.The condition of the iab as received indicated an occlusion in the inner lumen.We are unable to determine how this may have occurred.The evaluation confirmed the reported problem.Blood clotting within the inner lumen will seal the passage.It is difficult to determine when the occlusion occurs, however, if this occurs during the procedure it will be impossible to flush or aspirate through the inner lumen.It can also cause poor or no pressure waveform and guide wire insertion difficulty.A device and lot history record review was completed for the reported product.No nonconformances were found that are considered to be related to the event.Complaint #(b)(4); record id (b)(4).
 
Event Description
It was reported that after insertion of the intra-aortic balloon (iab) the physician could not aspirate blood from the inner lumen.The iab was replaced.There was no reported injury to the patient.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
LINEAR 7.5 FR. 40CC IAB
Type of Device
SYSTEM, BALLOON, INTRA-AORTIC AND CONTROL
Manufacturer (Section D)
DATASCOPE FAIRFIELD
15 law drive
fairfield NJ 07004
MDR Report Key8090707
MDR Text Key128211605
Report Number2248146-2018-00674
Device Sequence Number1
Product Code DSP
Combination Product (y/n)N
PMA/PMN Number
K041281
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 12/20/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/20/2018
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date06/11/2021
Device Catalogue Number0684-00-0475
Device Lot Number3000075440
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/26/2018
Device Age YR
Date Manufacturer Received11/26/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age70 YR
Patient Weight83
-
-