MAUDE Adverse Event Report: BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. BD CONNECTA¿ STOPCOCK

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. BD CONNECTA¿ STOPCOCK Back to Search Results
Catalog Number 394600
Device Problem Loose or Intermittent Connection (1371)
Patient Problem No Information (3190)
Event Date 11/06/2018
Event Type  malfunction  
Manufacturer Narrative
Date of event: unknown.A device evaluation is anticipated, but has not yet begun.Upon completion of the investigation, a supplemental report will be filed.
 
Event Description
It was reported that during use of the bd connecta¿ stopcock there was a loose connection.
 
Manufacturer Narrative
A device history review was conducted for lot number 8005644.Our records show the reported lot was manufactured on 01/17/2018, and determined that this is the only instance of this issue occurring in this batch of connecta.According to the sampling plan applied for product performance, this lot was accepted and released without defects being noted during the final assembly or visual inspections.Additionally during our review of the sample submitted by your facility, our engineers found the device to be functioning as expected, as the returned units remained successfully connected during course of functional testing.Our engineers have noted that the only known way to detach the luer connector is through the over-tightening of the component.Unfortunately based on our findings, the root cause for this complaint could not be determined at the conclusion of our review; bd will continue to track and trend for this issue.Customer reported difficult insertion/disconnection/difficult to operate, however, samples have been functional showing no problems.Quality records have been consulted for tracking and trending purposes and no issues like this are detected which means pretty low occurrence.(b)(4) were reviewed and there are proper controls in place to detect product malfunctions.Based on investigation results to date, root cause for manufacturing process cannot be determined.
 
Event Description
It was reported that during use of the bd connecta stopcock there was a loose connection.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BD CONNECTA¿ STOPCOCK
Type of Device
STOPCOCK
Manufacturer (Section D)
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
periferico luis donaldo
colosio no. 579
nogales
MDR Report Key8101613
MDR Text Key128566540
Report Number9610847-2018-00396
Device Sequence Number1
Product Code FMG
Combination Product (y/n)N
PMA/PMN Number
N/A
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Type of Report Initial,Followup
Report Date 12/19/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/26/2018
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date12/31/2020
Device Catalogue Number394600
Device Lot Number8005644
Date Manufacturer Received11/06/2018
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Other;
-
-