• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER Back to Search Results
Model Number 175818
Device Problems Deflation Problem (1149); Material Deformation (2976)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.The device was not returned.
 
Event Description
It was reported that the balloon on the foley catheter deflated prematurely.The patient reportedly experienced pain with the removal of the catheter.No medical intervention was required.The patient then re-inflated the balloon and allegedly observed that the balloon was larger on one side than the other.The complainant noted that the balloon was inflated with 10cc of fluid.
 
Manufacturer Narrative
The reported event was unconfirmed, since the product met specifications.Visual evaluation of the returned sample noted one opened (without original packaging), used silicone foley.Visual inspection of the sample noted no obvious visible defects.The catheter balloon was inflated with 10ml of methylene blue solution (3 drops 1% aq methylene blue per 100ml distilled water) and balloon concentricity was observed to be 60:40.The balloon rested for 30 minutes without leaks and passively deflated without issue, returning 10ml of solution.The drainage lumen was flushed with methylene blue solution (3 drops 1% aq methylene blue per 100ml of distilled water) with no leaks were observed.Active length of the catheter balloon was measured (0.7445") and found to be within specification (0.6"- 0.9").The inner diameter of the catheter funnel (0.3700") was in specification (0.36"±0.01").The catheter was confirmed to be 18 fr.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: ¿to deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.If you notice slow or no deflation, re-seat the syringe gently.Allow the balloon to deflate slowly on its own.Do not aspirate or manually accelerate the deflation of the balloon.If permitted by hospital protocol, the valve arm may be severed.If this fails, contact adequately trained professional for assistance, as directed by hospital protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.Visually inspect the product for any imperfections or surface deterioration prior to use.".
 
Event Description
It was reported that the balloon on the foley catheter deflated prematurely.The patient reportedly experienced pain with the removal of the catheter.No medical intervention was required.The patient then re-inflated the balloon and allegedly observed that the balloon was larger on one side than the other.The complainant noted that the balloon was inflated with 10cc of fluid.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARDEX® LUBRI-SIL® ALL-SILICONE FOLEY CATHETER
Type of Device
FOLEY CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key8209899
MDR Text Key132534580
Report Number1018233-2019-00017
Device Sequence Number1
Product Code EZL
UDI-Device Identifier00801741034176
UDI-Public(01)00801741034176
Combination Product (y/n)N
PMA/PMN Number
K040504
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,other
Type of Report Initial,Followup
Report Date 04/03/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date10/25/2021
Device Model Number175818
Device Catalogue Number175818
Device Lot NumberNGAX2668
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/08/2019
Initial Date Manufacturer Received 12/10/2018
Initial Date FDA Received01/02/2019
Supplement Dates Manufacturer Received03/18/2019
Supplement Dates FDA Received04/03/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-