Model Number 33618
Device Problems Deflation Problem (1149); Inflation Problem (1310)
Patient Problems No Consequences Or Impact To Patient (2199); No Known Impact Or Consequence To Patient (2692)
Event Date 12/14/2018
Event Type  malfunction  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete a supplemental report will be filed.
 
Event Description
It was reported that the balloon probe does not stay inflated when it was filled prior to inserting the catheter.
 
Manufacturer Narrative
The reported event was unconfirmed.A silastic foley was returned.The sample was received opened and without the original packaging.The device was received in good condition.Visual evaluation noted no obvious defects.The device was inflated with 10ml water using a leur lock syringe.The balloon remained inflated for approximately one minute.No leaks were observed.The balloon was manipulated and no water leaked.The device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: ¿warning: do not use ointments or lubricants having a petrolatum base.They will damage the catheter.This is a single use device.Do not resterilize any portion of this device.Reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient.Visually inspect the product for any imperfections or surface deterioration prior to use.Use luer tip syringe to inflate with stated ml of sterile water.Or for pre-filled products, remove clip and squeeze reservoir to inflate with stated ml of sterile water.Storage: store catheters at room temperature away from direct exposure to light, preferably in the original box.For urological use only.Do not use if package is damaged bard, bardex, and lubricath are trademarks and/or registered trademarks of c.R.Bard, inc.Single use do not resterilize manufacturer: to deflate catheter balloon: gently insert a luer slip tip syringe in the catheter valve.Never use more force than is required to make the syringe ¿stick¿ in the valve.Allow the pressure within the balloon to force the plunger back and fill the syringe with water.If you notice slow or no deflation, re-seat the syringe gently.Use only gentle aspiration to encourage deflation if needed.Vigorous aspiration may collapse the inflation lumen, preventing balloon deflation.If necessary, contact adequately trained professional for assistance, as directed by hospital protocol.Should balloon rupture occur, care should be taken to assure that all balloon fragments have been removed from the patient.".
 
Event Description
It was reported that the balloon probe does not stay inflated when it was filled prior to inserting the catheter.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
BARD® SILASTIC® FOLEY CATHETER
Type of Device
SILASTIC FOLEY CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key8237078
MDR Text Key132785427
Report Number1018233-2019-00222
Device Sequence Number1
Product Code EZL
UDI-Device Identifier00801741020070
UDI-Public(01)00801741020070
Combination Product (y/n)N
PMA/PMN Number
K951103
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,other
Type of Report Initial,Followup
Report Date 05/28/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Other
Device Expiration Date06/30/2021
Device Model Number33618
Device Catalogue Number33618
Device Lot NumberJD7225
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/01/2019
Initial Date Manufacturer Received 12/22/2018
Initial Date FDA Received01/10/2019
Supplement Dates Manufacturer Received05/15/2019
Supplement Dates FDA Received05/28/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-