TELEFLEX MEDICAL HUDSON NEBULIZER ADAPTOR 033,STERILE,JAPANESE; NEBULIZER (DIRECT PATIENT INTE Back to Search Results
Catalog Number 031-33J
Device Problem Connection Problem (2900)
Patient Problem No Patient Involvement (2645)
Event Date 12/20/2018
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been received by the manufacturer for evaluation at the time of this report.
 
Event Description
Customer complaint alleges when connecting the device the connection was unstable.No patient involvement was reported.
 
Manufacturer Narrative
(b)(4).The sample was returned for evaluation.A visual exam was performed and signs of use were observed.No other issues were found.During the setup of the oxygen entrainment test it was observed that the assembly of the nut adaptor and the upper body component was unstable, however the sample passed the testing.As an additional test the sample was tested on the oxygen entrainment test using a bottle of sterile water connected to the nebulizer adaptor in order to simulate the use of the customer and no issues were detected.After the testing was finished, the nut adaptor was carefully disassembled from the upper body and it was visually inspected.During the visual inspection it was found there was wear on the internal tabs.Based on the investigation performed, the reported complaint was confirmed.Although the condition was observed on the sample provided, there is not sufficient evidence to assure that this issue was originated during the manufacturing assembly or molding process.The wear on the internal tabs of the adaptor is most likely caused by the end user during the connection of the adaptor into the flowmeter that causes an unstable connection issue.
 
Event Description
Customer complaint alleges when connecting the device the connection was unstable.No patient involvement was reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HUDSON NEBULIZER ADAPTOR 033,STERILE,JAPANESE
Type of Device
NEBULIZER (DIRECT PATIENT INTE
Manufacturer (Section D)
TELEFLEX MEDICAL
research triangle park NC
MDR Report Key8264053
MDR Text Key133844333
Report Number3004365956-2019-00015
Device Sequence Number1
Product Code CAF
Combination Product (y/n)N
PMA/PMN Number
K153010
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 12/27/2018
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator No Information
Device Catalogue Number031-33J
Device Lot Number74I1701439
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/07/2019
Initial Date Manufacturer Received 12/27/2018
Initial Date FDA Received01/21/2019
Supplement Dates Manufacturer Received02/22/2019
Supplement Dates FDA Received02/25/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
NONE REPORTED.; NONE REPORTED.
-
-