Catalog Number 0375704500E
Device Problem Overheating of Device (1437)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 02/22/2019
Event Type  malfunction  
Manufacturer Narrative
Additional information will be provided once the investigation has been completed.
 
Event Description
It was reported that the product heated up.
 
Manufacturer Narrative
The product was not returned for investigation therefore the reported failure mode was not confirmed.Alleged failure: the practitioner broke 2 strawberries during use.Probable root cause: - inadequate window profile - inadequate welding process - improper material strength - inadequate size selected for the application - material brittleness - excessive force applied by the user - incorrect rfid tag.The failure mode will be monitored for future reoccurrence.
 
Event Description
It was reported that the product heated up.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
KIT, FORMULA H/C SHAVER
Type of Device
BUR, SURGICAL, GENERAL & PLASTIC SURGERY
Manufacturer (Section D)
STRYKER ENDOSCOPY-SAN JOSE
5900 optical court
san jose CA 95138
MDR Report Key8453152
MDR Text Key139976115
Report Number0002936485-2019-00114
Device Sequence Number1
Product Code GFF
UDI-Device Identifier07613327057638
UDI-Public07613327057638
Combination Product (y/n)N
PMA/PMN Number
EXEMPT
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 06/06/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received03/26/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number0375704500E
Device Lot Number15188CE2
Was Device Available for Evaluation? No
Date Manufacturer Received02/26/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-