• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: MEDTRONIC HEART VALVES DIVISION FREESTYLE AORTIC ROOT BIOPROSTHESIS; HEART-VALVE, NON-ALLOGRAFT TISSUE

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

MEDTRONIC HEART VALVES DIVISION FREESTYLE AORTIC ROOT BIOPROSTHESIS; HEART-VALVE, NON-ALLOGRAFT TISSUE Back to Search Results
Model Number FR995-27
Device Problem Insufficient Information (3190)
Patient Problem Vascular Dissection (3160)
Event Date 04/01/2019
Event Type  Injury  
Manufacturer Narrative
Conclusion: without the return of the product, no definitive conclusion can be made regarding the clinical observation.If information is provided in the future, a supplemental report will be issued.
 
Event Description
Medtronic received information that immediately post implant of this 27mm aortic bioprosthetic valve in a patient with a native bicuspid aortic valve, the surgeon noted bleeding from the graft.It was identified that the muscular tissue had "dislodged and dissected" from the cuff between the right and non-coronary.During the initial implant, the surgeon created buttons, cut out the native leaflets and made a felt gasket.The valve was ultimately explanted after the bleeding was identified, and was replaced with a non-medtronic valve, which extended the procedure an additional hour.No additional adverse patient effects were reported. .
 
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FREESTYLE AORTIC ROOT BIOPROSTHESIS
Type of Device
HEART-VALVE, NON-ALLOGRAFT TISSUE
Manufacturer (Section D)
MEDTRONIC HEART VALVES DIVISION
1851 e deere ave
santa ana CA 92705
MDR Report Key8518854
MDR Text Key142086679
Report Number2025587-2019-01220
Device Sequence Number1
Product Code LWR
UDI-Device Identifier00643169008137
UDI-Public00643169008137
Combination Product (y/n)N
PMA/PMN Number
P970031
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 05/09/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date04/03/2023
Device Model NumberFR995-27
Device Catalogue NumberFR995-27
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 04/01/2019
Initial Date FDA Received04/16/2019
Supplement Dates Manufacturer Received04/16/2019
Supplement Dates FDA Received05/09/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age71 YR
Patient Weight120
-
-