Model Number G148
Device Problem Under-Sensing (1661)
Patient Problems Syncope (1610); Fall (1848)
Event Date 03/22/2019
Event Type  Injury  
Event Description
It was reported that this cardiac resynchronization therapy defibrillator (crt-d) patient experienced a syncopal episode and fell and hit their head.The right ventricular (rv) lead exhibited undersensing and therapy was delayed for less than 30 seconds.The patient reported their lead was bent.Subsequently, a revision procedure was performed.The crt-d and rv lead were explanted and replaced.No additional adverse patient effects were reported.
 
Event Description
Additional information was received which indicated the cause of the undersensing was due to very low amplitude of the r-waves.No additional adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
INOGEN X4 CRT-D
Type of Device
DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER, WITH CRT-D
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CLONMEL LIMITED
cashel road
,
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
,
saint paul, MN 55112
6515826168
MDR Report Key8594396
MDR Text Key144526134
Report Number2124215-2019-09587
Device Sequence Number1
Product Code NIK
UDI-Device Identifier00802526534591
UDI-Public00802526534591
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P010012/S341
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,consum
Reporter Occupation Other
Type of Report Initial,Followup
Report Date 06/04/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date08/31/2018
Device Model NumberG148
Device Catalogue NumberG148
Device Lot Number156208
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? No
Initial Date Manufacturer Received 03/22/2019
Initial Date FDA Received05/09/2019
Supplement Dates Manufacturer Received05/10/2019
Supplement Dates FDA Received06/04/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/15/2016
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Life Threatening; Required Intervention;
Patient Age47 YR
-
-