Catalog Number UNK HIP FEMORAL STEM
Device Problem Loss of Osseointegration (2408)
Patient Problems Inflammation (1932); Pain (1994); Pocket Erosion (2013); Injury (2348); Osteolysis (2377); Inadequate Osseointegration (2646); Test Result (2695); No Code Available (3191)
Event Date 08/28/2017
Event Type  Injury  
Manufacturer Narrative
Product complaint # (b)(4).Initial reporter occupation: lawyer.(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Pinnacle claim submission form and medical record received.After review of medical records, the patient was revised to address periprosthetic osteolysis.Revision notes reported that there is a clear yellow fluid noted within the hip joint, erosion is noted at the trunnion, visibly loose proximal aspect of the femoral stem, black brown inflammatory tissue, synovitis with black stained material, and osteolysis due to metal wear.A trochanteric osteotomy was done to remove the stem since there was still bone ingrowth distally; this was then cabled.Clinical visits reported elevated metal ions and pain.Doi: (b)(6) 2007 - dor: (b)(6) 2017, (left hip).
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provisions of 21 cfr, part 803.This report may be based on information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.A worldwide lot specific complaint database search, or device history record (dhr) review, was not possible because the required lot number was not provided.Based on previous investigations, this complication of joint replacement is unlikely to have been the result of a device failing to meet required specifications.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.If information is obtained that was not available for the initial medwatch, a follow-up medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL STEM
Type of Device
HIP FEMORAL STEM
Manufacturer (Section D)
DEPUY ORTHOPAEDICS, INC. 1818910
700 orthopaedic drive
warsaw IN 46582 0988
MDR Report Key8687107
MDR Text Key147648373
Report Number1818910-2019-95676
Device Sequence Number1
Product Code KWY
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Type of Report Initial,Followup
Report Date 05/22/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL STEM
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 05/22/2019
Initial Date FDA Received06/11/2019
Supplement Dates Manufacturer Received06/19/2019
Supplement Dates FDA Received06/19/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age72 YR
Patient Weight101
-
-