Model Number UNKNOWN-S
Device Problem Disconnection (1171)
Patient Problems Headache (1880); Seizures (2063); Lethargy (2560)
Event Date 08/01/2016
Event Type  Injury  
Manufacturer Narrative
If information is provided in the future, a supplemental report will be issued.
 
Event Description
It was reported that on the evening of (b)(6) 2016, the patient presented to the emergency room with a one week history of worsening headaches, lethargy, and a complex partial seizure.A ct scan revealed enlarged ventricles and midline intraventricular cyst with evidence of a catheter disconnect distal to the valve in the neck.Aspiration of their ventriculoperitoneal shunt valve reservoir which was set at 2.0 yielded several milliliters of clear cerebrospinal fluid without evidence of infection.The entire shunt system was replaced due to the patient suffering from a distal shunt malfunction with at least partial obstruction to their normal cerebrospinal fluid flow through the shunt due to the break, and given the fact that the existing ventricular catheter was also not in an ideal location.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN STRATA VALVE/SHUNT
Type of Device
SHUNT, CENTRAL NERVOUS SYSTEM AND COMPONENTS
Manufacturer (Section D)
MEDTRONIC NEUROSURGERY
125 cremona drive
goleta CA 93117
Manufacturer (Section G)
MEDTRONIC NEUROSURGERY
125 cremona drive
goleta CA 93117
Manufacturer Contact
stacy ruemping
7000 central avenue ne rcw215
minneapolis, MN 55432
7635260594
MDR Report Key8696105
MDR Text Key147905389
Report Number2021898-2019-00232
Device Sequence Number1
Product Code JXG
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Reporter Occupation Non-Healthcare Professional
Type of Report Initial
Report Date 06/13/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/13/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberUNKNOWN-S
Device Catalogue NumberUNKNOWN-S
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Date Manufacturer Received05/15/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age12 YR
-
-