Model Number M00542251 |
Device Problem
Premature Activation (1484)
|
Patient Problem
No Consequences Or Impact To Patient (2199)
|
Event Date 01/25/2018 |
Event Type
malfunction
|
Manufacturer Narrative
|
(b)(4).The device has not been received for analysis.Upon receipt and completion of the failure analysis of the complaint device, if there is any further relevant information from that review, a supplemental mdr will be filed.
|
|
Event Description
|
It was reported to boston scientific corporation that a speedband superview super 7 device was used in the esophagus during an endoscopic variceal ligation (evl) procedure performed on (b)(6) 2018.According to the complainant, during the procedure, the device released several bands continuously.The procedure was completed with another speedband superview super 7 device.There were no patient complications reported as a result of this event.
|
|
Event Description
|
It was reported to boston scientific corporation that a speedband superview super 7 device was used in the esophagus during an endoscopic variceal ligation (evl) procedure performed on (b)(6) 2018.According to the complainant, during the procedure, the device released several bands continuously.The procedure was completed with another speedband superview super 7 device.There were no patient complications reported as a result of this event.
|
|
Manufacturer Narrative
|
Block h6: problem code 1484 relates to the reportable issue of bands prematurely deployed.Block h10: investigation results a speedband superview super 7 was returned with the ligator head for analysis.A visual examination of the ligator head found 7 bands were present in their original position and there was no damage or abnormalities found.It was noticed that the ligature head teeth were not bent/kinked.A functional evaluation was performed by rotating the handle knob 180 degrees, an audible click was heard and indents were felt.No issue was noted with the handle assembly, suture and ligator head, and the returned product looks in good conditions without evidence of damages.Based on the evaluation of the returned device, the device showed neither evidence of the alleged issue nor any defect which could have contributed to the complaint.Therefore, it was concluded that the investigation conclusion code of this event is "no problem detected" since the device complaint or problem cannot be confirmed.A review of the device history record (dhr) was performed and confirmed that this device met all material, assembly and performance specifications.
|
|