ABBVIE - MEDICAL DEVICE CENTER DUODOPA_DUOPA; TUBES, GASTROINTESTINAL (AND ACCESSORIES) Back to Search Results
Catalog Number 062941
Device Problem Insufficient Information (3190)
Patient Problem No Code Available (3191)
Event Date 06/16/2019
Event Type  Injury  
Manufacturer Narrative
Reference record (b)(4).Catalog number is the international list number which is similar to us list number of 062910.The device involved in the event remained implanted in the patient and was not returned; therefore, a return sample evaluation is unable to be performed.If any further relevant information is identified or obtained, a supplemental medwatch will be filed.
 
Event Description
On (b)(6) 2019, a patient in (b)(6) underwent a procedure for the placement of percutaneous endoscopic gastrostomy (peg) tube with jejunal (peg-j) tube.On (b)(6) 2019, the patient experienced abdominal pain and liquid in the peritoneum.On (b)(6) 2019, an exploratory laparotomy was performed, and it was discovered that during the peg-j placement, the round ligament of the liver was damaged.This caused an incorrect placement of the peg tube, allowing gastric fluid to leak into the peritoneum.The patient was subsequently hospitalized.On an unknown date, the j-tube was endoscopically removed.The peg tube was left in place.The j-tube replacement was postponed.No further information was received.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DUODOPA_DUOPA
Type of Device
TUBES, GASTROINTESTINAL (AND ACCESSORIES)
Manufacturer (Section D)
ABBVIE - MEDICAL DEVICE CENTER
1675 lakeside drive
waukegan IL 60085
Manufacturer (Section G)
ABBVIE - MEDICAL DEVICE CENTER
1675 lakeside drive
waukegan IL 60085
Manufacturer Contact
terry ingram
1675 lakeside drive
waukegan, IL 60085
8479385350
MDR Report Key8846272
MDR Text Key152796258
Report Number3010757606-2019-00522
Device Sequence Number1
Product Code KNT
Combination Product (y/n)N
Reporter Country CodeIT
PMA/PMN Number
K142793
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,o
Reporter Occupation Physician
Remedial Action Other
Type of Report Initial
Report Date 06/16/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number062941
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Initial Date Manufacturer Received 06/16/2019
Initial Date FDA Received07/31/2019
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
UNKNOWN J-TUBE - LOT # UNKNOWN
Patient Outcome(s) Hospitalization; Required Intervention;
Patient Age64 YR
-
-