ZIMMER BIOMET, INC. G7 CURVED INSERTER THD SHAFT; PROSTHESIS, HIP Back to Search Results
Model Number N/A
Device Problems Mechanical Problem (1384); Detachment of Device or Device Component (2907)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 07/08/2019
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Product has been received by zimmer biomet and the investigation is in process.Once the investigation has been completed, a follow-up mdr will be submitted.Concomitant medical products: item number: 110010247, item name: g7 osseoti shell, lot #: 6382348.Foreign report source: (b)(6).Multiple mdr reports were filed for this event, please see associated reports: 0001825034 - 2019 - 03408.
 
Event Description
It was reported that the acetabular shell detached from the shell inserter during impaction.A different shell was used to complete the case.No patient harm was indicated.No additional information is available at this time.
 
Event Description
No further event information available at the time of this report.
 
Manufacturer Narrative
This follow-up report is being submitted to relay additional information.Reported event was confirmed with product return.Visual inspection of the inserter identified damages to the threads.The shell shows damage around the square locking feature and also damage to the threads.These damages were likely during an attempt to impact the inserter with the shell.It is unknown how many times the device was used.Review of the device history records identified no related deviations or anomalies during manufacturing.The damages suggest that the inserter was likely malaligned during the procedure; however a definitive root cause cannot be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
G7 CURVED INSERTER THD SHAFT
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key8855698
MDR Text Key153132478
Report Number0001825034-2019-03406
Device Sequence Number1
Product Code PBI
Combination Product (y/n)N
PMA/PMN Number
K121874
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/20/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/02/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number110003454
Device Lot Number400998
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/29/2019
Was the Report Sent to FDA? No
Date Manufacturer Received01/16/2020
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-