• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: C.R. BARD, INC. (COVINGTON) -1018233 OEM - BALLOON BIPOLAR TEMPORARY PACING ELECTRODE, 5FR 110CM, STRAIGHT; TEMPORARY PACING ELECTRODE CATHETER

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

C.R. BARD, INC. (COVINGTON) -1018233 OEM - BALLOON BIPOLAR TEMPORARY PACING ELECTRODE, 5FR 110CM, STRAIGHT; TEMPORARY PACING ELECTRODE CATHETER Back to Search Results
Model Number 106173P
Device Problems Inflation Problem (1310); Leak/Splash (1354)
Patient Problems Low Blood Pressure/ Hypotension (1914); Pericardial Effusion (3271)
Event Date 07/23/2019
Event Type  Injury  
Manufacturer Narrative
The investigation is still in progress.Once the investigation is complete, a supplemental report will be filed.
 
Event Description
It was reported that the temporary pacing electrode catheter would not stay inflated during a transcatheter aortic valve replacement (tavr) procedure despite locking on the proximal end.The surgeon normally uses catalog number 520007p, which he has used successfully for years, but it is on back order at this time.He had to use catalog number 106173p as a replacement, which does not have the "right heart curvature" like the catheter he normally uses.The surgeon had to manually place a curve on the distal tip because this catheter was more pointed, and sphere-like compared to the other catheter.A (b)(6) year old male underwent a scheduled tavr procedure in the cardiac interventional lab.The surgeon kept the delivery system and the wires in place and ordered a stat echocardiogram after the valve was placed to assess for a pericardial effusion.The surgeon's last tavr case experienced an effusion and expired, reportedly due to complications of the procedure on the same date.The echocardiogram showed a large pericardial effusion with hypotension.Vasopressors were started and an emergent pericardial window was performed.When the patient's blood pressure stabilized, the delivery system and pacing wires were removed, a pericardial drain was placed.The window was closed with sutures.
 
Event Description
It was reported that the temporary pacing electrode catheter would not stay inflated during a transcatheter aortic valve replacement (tavr) procedure despite locking on the proximal end.The surgeon normally uses catalog number 520007p, which he has used successfully for years, but it is on back order at this time.He had to use catalog number 106173p as a replacement, which does not have the "right heart curvature" like the catheter he normally uses.The surgeon had to manually place a curve on the distal tip because this catheter was more pointed, and sphere-like compared to the other catheter.A 77 year old male underwent a scheduled tavr procedure in the cardiac interventional lab.The surgeon kept the delivery system and the wires in place and ordered a stat echocardiogram after the valve was placed to assess for a pericardial effusion.The surgeon's last tavr case experienced an effusion and expired, reportedly due to complications of the procedure on the same date.The echocardiogram showed a large pericardial effusion with hypotension.Vasopressors were started and an emergent pericardial window was performed.When the patient's blood pressure stabilized, the delivery system and pacing wires were removed, a pericardial drain was placed.The window was closed with sutures.
 
Manufacturer Narrative
The reported event was unconfirmed.A temporary pacing electrode was returned still attached to a remington connector cable.The original argon packaging was also returned.A separate sealed temporary pacing electrode was returned in its original packaging.Functional evaluation: the used temporary pacing electrode's stopcock was opened and was inflated with 1.5 ccs of air using the attached syringe.The stopcock was closed and the balloon remain inflated.The balloon was placed in water for about a minute and no air bubbles were noticed.The second catheter was removed from its packaging and inflated with 1.5 ccs using the syringe found inside its kit.The stopcock was closed and the balloon remained inflated.The balloon was placed in the water for about one minute.No leaks were found.Both products meet specifications, "balloon to be capable of model inflation with 1.5 ml of air with no deflation for 30 seconds." the device history record was reviewed and found nothing that could have caused or contributed to the reported event.The instructions for use were found adequate and state the following: "¿temporary pacing electrode catheter information for use read this document in its entirety prior to use.Single use.Sterile, non-pyrogenic store in a cool, dry place.Caution: federal (u.S.A.) law restricts this device to sale by or on the order of a physician.Description bard® temporary pacing catheters are constructed of a woven or extruded polyurethane shaft with platinum or stainless steel electrodes.Certain catheters may incorporate one or more lumens for fluid infusion, pressure monitoring, blood sampling, or balloon inflation.The balloons are manufactured using latex material.Some product may be packaged with accessories such as a needle cannula, safety lead adapter, an ecg adapter, or a balloon inflation syringe.Indications for use bard® temporary pacing catheters are designed to transmit an electrical signal from an external pulse generator to the heart or from the heart to a monitoring device.When an internal lumen is present (other than the one used for balloon inflation), it may be used for fluid infusion, pressure monitoring, or blood sampling.Contraindications none.Warnings general warnings these warnings apply to all bard® temporary pacing electrode catheters.¿inappropriate electrical connections, e.G.Into a wall socket, may pose serious risk of adverse health consequences or death.¿please ensure that the catheter is connected as recommended for pacing or measuring intracardiac electrograms.¿this device should be used only by or under the supervision of physicians trained in the techniques of transvenous intracardiac studies and temporary pacing.¿this device is for one time use only.Reuse or resterilization can impair the structural integrity and/or performance of the catheter.Adverse patient reactions can also result from reuse.¿reuse and/or repackaging may create a risk of patient or user infection, compromise the structural integrity and/or essential material and design characteristics of the device, which may lead to device failure, and/or lead to injury, illness or death of the patient.¿the risks of using temporary pacing catheters include those risks related to heart catheterization, such as thromboembolism, perforation, tamponade, and infection.The induction of an unintended arrhythmia is a known complication.Warning for open lumen temporary pacing electrode catheters if using an open lumen catheter, remove any guidewire/stylette prior to electrical stimulation.Warnings for balloon temporary pacing electrode catheters ¿do not inflate balloon beyond stated maximum inflation capacity of 1.5 ml.¿balloon must be completely deflated before withdrawal of the electrode catheter.¿if the balloon catheter has been inflated in vivo for more than one minute, completely deflate the balloon and reinflate it to the recommended capacity of 1.5 ml.This is recommended because carbon dioxide diffuses through the latex balloon.Warnings for heparin bonded catheters ¿long-term pacing: although the surface of the catheter has been treated with an anticoagulant to minimize thromboembolic complications, the possibility of thromboembolic and infectious complications increases with the length of time of catheterization.The duration of catheterization should, therefore, be limited to the minimum required by the patient's condition.Prophylactic systemic anticoagulant and antibiotic protection should be considered in cases with increased risks and when long-term catheterization (longer then 48 hours) is necessary.The biological activity of the heparin bonding is initiated by blood contact, therefore, efficacy of the bonding is limited to one patient use only.¿it has been reported that heparin induced thrombocytopenia has, in some cases, been associated with the use of heparin bonded catheters.Patients exhibiting symptoms of thrombocytopenia should be monitored for a marked reduction in platelet count and for the presence of heparin associated antiplatelet antibodies.If the condition is confirmed, the physician must remove the catheter if thrombocytopenia is to be reversed and further complications avoided.Precautions ¿excessive bending, torquing, or kinking of the electrode catheter may cause damage to the catheter including damage to internal wires.¿when using a balloon catheter, use care when removing the protective sleeve from the distal portion of the catheter.Forced removal of this protective sleeve may result in damage to the balloon and the catheters structural integrity.¿for non heparin bonded catheters only: when wiping down this catheter, use only sterile saline.¿for those catheters that are heparin bonded, the following precautions apply: anticoagulant bonding: since the surface of the catheter shaft is treated with a heparin bonding, do not wipe the shaft with alcohol, its esters or ethers, or phenol compounds lest the bonding be rubbed off.If wound closure is prolonged, an appropriate topical hemostatic agent should be used to neutralize the effect of any heparin that may have been wiped off at the edge of the wound.Longer compression time at the insertion site may be required.The packaging is designed to avoid crushing of the catheter and to help protect the heparin bonding on the surface of the catheter.The heparin treated surfaces are fragile.As a result, reasonable care should be employed when removing the catheter from the package.¿ after use, this product may be a potential biohazard.Handle and dispose of in accordance with accepted medical practice and applicable local, state, and federal laws.Instructions for use inspection instructions 1.Inspect the sterile package carefully for damage during transit or storage.Do not use the catheter if the package is damaged.2.Visually inspect the catheter, under sterile conditions, for kinks in the catheter shaft, integrity of the connector, condition of electrodes, and any other damage.3.In case of catheters with a balloon, under sterile conditions, remove the protective sheath and inflate the balloon with 1.5 ml of air or carbon dioxide.Use the inflation syringe included in the package.Completely deflate the balloon after the test.Insertion instructions using a needle cannula 1.Open the package and place the contents on a sterile field.2.Prep the skin at the site of insertion and inject a local anesthetic.3.Remove the protective guard from the needle cannula.4.Enter the vein with the needle cannula.Simultaneous aspiration into a syringe will help confirm vessel entry.5.Remove the syringe and the needle.6.If using an open-lumen catheter, flush the catheter with a heparinized solution.Remove any stylette prior to insertion.7.Using the aid of fluoroscopy or an ecg monitor, advance the catheter through the cannula to the desired position.If using a balloon catheter, inflate the balloon when the catheter is in the right atrium.Please note that the balloon can be inflated or deflated only when the stopcock is parallel to the catheter shaft.Do not pull the catheter back through the cannula as it may cause damage to the catheter.8.If using a balloon catheter, deflate the balloon after the catheter has reached the desired location.9.Test the pacing characteristics for optimal pacing.10.Pull the cannula back and secure it to the proximal end of the catheter.11.Secure the electrode catheter in place at the insertion site.Insertion instructions using a percutaneous introducer sheath follow the instructions, warnings, and precautions of the introducer manufacturer.If using a balloon temporary pacing catheter, use half or one french size larger introducer, unless otherwise recommended by the introducer manufacturer.Electrical connections for measuring intracardiac ecgs 1.Insert adapter pin into standard 2 mm (0.080¿) pin receptacle of equipment (see figure 1).If equipment contains a locking mechanism such as a collet or thumbscrew, tighten down onto adapter.Leave affixed to equipment.Warning: inappropriate electrical connections, e.G.Into a wall socket, may pose serious risk of adverse health consequences or death.2.Thread leads of catheter through the adapter eyelet.Connect the negative jack (marked ¿distal¿) to the v-lead of the ecg, and the positive jack (unmarked) to the positive terminal of the external pulse generator.Electrical connections for pacing 1.Insert adapter pin into standard 2 mm (0.080¿) pin receptacle of equipment (see figure 1).If equipment contains a locking mechanism such as a collet or thumbscrew, tighten down onto adapter.Leave affixed to equipment.Warning: inappropriate electrical connections, e.G.Into a wall socket, may pose serious risk of adverse health consequences or death.2.Thread leads of catheter through the adapter eyelet.Connect the negative jack (marked distal) to the negative terminal of the external pulse generator, and the positive jack (unmarked) to the positive terminal of the pulse generator.".
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
OEM - BALLOON BIPOLAR TEMPORARY PACING ELECTRODE, 5FR 110CM, STRAIGHT
Type of Device
TEMPORARY PACING ELECTRODE CATHETER
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
MDR Report Key8897247
MDR Text Key154443570
Report Number1018233-2019-04746
Device Sequence Number1
Product Code LDF
UDI-Device Identifier00801741011573
UDI-Public(01)00801741011573
Combination Product (y/n)N
PMA/PMN Number
K800298
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other,user facility
Type of Report Initial,Followup
Report Date 09/12/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Device Operator Health Professional
Device Expiration Date05/31/2021
Device Model Number106173P
Device Catalogue Number106173P
Device Lot NumberGFDR0478
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/07/2019
Initial Date Manufacturer Received 07/24/2019
Initial Date FDA Received08/15/2019
Supplement Dates Manufacturer Received09/11/2019
Supplement Dates FDA Received09/12/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Life Threatening; Required Intervention;
Patient Age77 YR
-
-