Catalog Number 09H39-01
Device Problem High Test Results (2457)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Type  malfunction  
Manufacturer Narrative
Patient information: no further patient information was provided by the customer.An evaluation is in process.A follow-up report will be submitted when the evaluation is complete.
 
Event Description
The customer observed falsely elevated platelet results generated on cell dyn emerald for 2 samples.The following data was provided (units of measure = k/ul): sample 1 initial result = 1389, repeat after bleaching analyzer = 217.Sample 2 initial result = 935, repeat after bleaching analyzer = 363.No impact to patient management was reported.
 
Manufacturer Narrative
Abbott field service (fs) performed on site troubleshooting and found rbc count chamber tube was discolored.Platelet issue resolved by replacing count chamber assembly and related count head.A review of product historical data did not identify any trends or abnormal complaint activity for this issue.A review of the manufacturing documentation did not identify any issues associated with the complaint issue.A review of labeling concluded that the issue is sufficiently addressed.Based on the investigation no systemic issue or deficiency of the cell-dyn emerald analyzer was identified.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CELL-DYN EMERALD ANALYZER
Type of Device
AUTOMATED HEMATOLOGY ANALYZER
Manufacturer (Section D)
ABBOTT DIAGNOSTICS DIVISION
4551 great america parkway
santa clara CA 95054
MDR Report Key8898647
MDR Text Key184175981
Report Number2919069-2019-00091
Device Sequence Number1
Product Code GKZ
UDI-Device Identifier00380740020088
UDI-Public00380740020088
Combination Product (y/n)N
PMA/PMN Number
K081495
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Type of Report Initial,Followup
Report Date 08/29/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/15/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number09H39-01
Was Device Available for Evaluation? Yes
Date Manufacturer Received08/28/2019
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-