Model Number N/A
Device Problem Positioning Failure (1158)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 09/25/2019
Event Type  malfunction  
Manufacturer Narrative
(b)(4).Concomitant medical product: catalog# 010000757, g7 10 deg arcomxl liner 28mm a, lot# 3882068.Catalog# 010000913, g7 hi-wall e1 liner 28mm a, lot# 6167725.Catalog# 010000874, g7 10 deg e1 liner 28mm a, lot# 6569774.Catalog# 110003625, biolox delta cer lnr 28mm b, lot# 6022564.Catalog# 650-0830, delta cer fm hd 028/-3.5 12/14, lot# 2019020164.Catalog# 010000660, g7 pps ltd acet shell 46b, lot# 6360904.Catalog# 650-0951, micro tprlc std pc 6mm (12/14), lot# 6594650.Report source : (b)(6).Customer has indicated that the product is in process of being returned to zimmer biomet for investigation.Once the investigation has been completed, a follow-up mdr will be submitted.Multiple mdr reports were filed for this event, please see associated reports: 0001825034-2019-04417, 0001825034-2019-04418, 0001825034-2019-04420.
 
Event Description
It was reported that the liner would not lock in the acetabular shell.Surgeon used another, larger shell and liner to complete the surgery.Attempts have been made and additional information on the reported event is unavailable at this time.
 
Event Description
No further event information available at the time of this report.
 
Manufacturer Narrative
Udi#: (b)(4).The event was confirmed with product received.Visual inspection found light scratches on the inner radius and rim of the shell.No damage was observed to the locking groove or orientation feature.The apical plug was also returned with the complaint.Dhr was reviewed and no discrepancies relevant to the reported event were found.Root cause was unable to be determined.If any further information is found which would change or alter any conclusions or information, a supplemental will be filed accordingly.Zimmer biomet will continue to monitor for trends.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
G7 PPS LTD ACET SHELL 44A
Type of Device
PROSTHESIS, HIP
Manufacturer (Section D)
ZIMMER BIOMET, INC.
56 e. bell drive
warsaw IN 46582
MDR Report Key9146826
MDR Text Key204711093
Report Number0001825034-2019-04419
Device Sequence Number1
Product Code PBI
Combination Product (y/n)N
PMA/PMN Number
K121874
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,foreign,health pr
Type of Report Initial,Followup
Report Date 01/29/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/02/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberN/A
Device Catalogue Number010000659
Device Lot Number6129679
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer11/22/2019
Was the Report Sent to FDA? No
Date Manufacturer Received01/27/2020
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
-
-