MAUDE Adverse Event Report: TOSOH CORPORATION AIA-900

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TOSOH CORPORATION AIA-900 Back to Search Results
Model Number AIA-900
Device Problem Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 10/11/2019
Event Type  malfunction  
Manufacturer Narrative
A 13-month complaint history review and service history review for similar complaints was performed for ipth lot iz15222 and serial number (b)(4) through aware date of event.There were no similar complaints identified during the searched period.The intact parathyroid hormone st aia-pack intact pth analyte application manual states the following: evaluation of results quality control in order to monitor and evaluate the precision of the analytical performance, it is recommended that commercially available control samples be assayed daily.The minimum recommendations for the frequency of running internal control material are: after calibration, two levels of controls are run in order to accept the calibration curve.The two levels of controls are also repeated after calibration when certain service procedures are performed (e.G.Temperature adjustment, sampling mechanism changes, maintenance of the wash probe or detector lamp adjustment or change).After daily maintenance, at least two levels of the control should be run in order to verify the overall performance of the tosoh aia system analyzers.If one or more control sample value(s) is out of the acceptable range, it will be necessary to investigate the validity of the calibration curve before reporting patient results.Standard laboratory procedures should be followed in accordance with the regulatory agency under which the laboratory operates.Limitations of the procedure for diagnostic purposes, the results obtained from this assay should be used in conjunction with other data (e.G., symptoms, results of other tests, clinical impressions, therapy, etc.).Using st aia-pack intact pth, the highest concentration of intact parathyroid hormone measurable without dilution is approximately 2,000 pg/ml, and the lowest measurable concentration is 1.0 pg/ml (assay sensitivity).The most probable cause of the reported event is unknown, possible reagent compromised during shipping.
 
Event Description
A customer reported out of range control results with the aia-900 analyzer.The customer stated they have had to recalibrate 3 times in the last month with intact parathyroid hormone (ipth) lot iz15222, which expires the end of nov 2019.Technical support specialist (tss) will send a new lot of ipth and calibrator to the customer, which resulted in delayed reporting of patient samples for ipth.The customer received the ipth calibrator lot iz15222.Customer calibrated lot iz15222 and the controls are still low.Customer then calibrated with lot j615231 and controls are in range.Tss suspects the lot iz15222 was compromised during shipping.A new lot will be sent to the customer.No further action was required by tosoh.There was no indication of patient intervention or adverse health consequences due to the delay in reporting.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AIA-900
Type of Device
AIA-900
Manufacturer (Section D)
TOSOH CORPORATION
shiba-koen first building
3-8-2 shiba
minato-ku, 10586 23
JA  1058623
Manufacturer (Section G)
TOSOH CORPORATION
shiba-koen first building
3-8-2 shiba
minato-ku, 10586 23
JA   1058623
Manufacturer Contact
bernadette oconnell
shiba-koen first building
3-8-2 shiba
minato-ku, tokyo 10586-23
JA   1058623
MDR Report Key9297704
MDR Text Key220028843
Report Number8031673-2019-00436
Device Sequence Number1
Product Code KHO
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K971103
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 11/08/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/08/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberAIA-900
Device Catalogue Number022930111
Was Device Available for Evaluation? Yes
Is the Reporter a Health Professional? Yes
Date Manufacturer Received10/11/2019
Was Device Evaluated by Manufacturer? No
Date Device Manufactured05/01/2017
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-