Catalog Number 00880100100
Device Problem Calibration Problem (2890)
Patient Problem Laceration(s) (1946)
Event Date 10/10/2019
Event Type  malfunction  
Manufacturer Narrative
This event has been recorded by zimmer biomet under (b)(4).Evaluation and investigation is in process.Once the investigation is complete, a supplemental medwatch will be filed.
 
Event Description
It has been reported that the device was taking thick grafts.Surgery time was not effected.No additional graft was taken.No adverse events were reported as a result of this malfunction.
 
Manufacturer Narrative
This event has been recorded by zimmer biomet under (b)(4).This medwatch is being filed to relay additional information.The following sections were updated/corrected: b1, b4, b5, d4, d10, g4, g7, h2, h3, h6 and h10.The device history record (dhr) and previous repair report reviewed noted no related non-conformances, requests for deviation, change notices or any other issues with manufacturing or with the device.The dhr and previous repair report review also found that all verifications, inspections and tests were successfully completed.Product review of the air dermatome by zimmer biomet taiwan on november 4, 2019 revealed that the motor speed was below specifications.The calibration was out of specifications at all settings and the control bar was in the correct position.The customer width plates were not returned for evaluation.Repair of the air dermatome was performed by zimmer biomet taiwan on november 6, 2019 which included replacement of the motor, bearings, o-ring, seal, reciprocating arm, external e-ring, machined head, and throttle hinge gasket.Air dermatome, serial number (b)(4), was then tested and functioned properly.It was repaired, inspected and tested.While the returned product investigation confirmed that the air dermatome was out of calibration at all settings, it cannot be determined from the information provided what actually caused the reported event.Therefore, based on the information provided, a specific root cause of the reported event cannot be determined.The device was noted to be functioning as intended after the unit was recalibrated and the motor, bearings, o-ring, seal, reciprocating arm, external e-ring, machined head, and throttle hinge gasket were replaced.The investigation was based on the information that was provided initially and any information that was obtained throughout the follow-up process.
 
Event Description
No additional event information.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ZIMMER AIR DERMATOME
Type of Device
DERMATOME
Manufacturer (Section D)
ZIMMER SURGICAL, INC.
200 west ohio avenue
dover OH 44622
MDR Report Key9328029
MDR Text Key166557150
Report Number0001526350-2019-01013
Device Sequence Number1
Product Code GFD
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,user facility
Type of Report Initial,Followup
Report Date 01/07/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/15/2019
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number00880100100
Device Lot Number62682589
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/25/2019
Was the Report Sent to FDA? No
Date Manufacturer Received12/17/2019
Is This a Reprocessed and Reused Single-Use Device? No
Removal/Correction NumberN/A
Patient Sequence Number1
Patient Outcome(s) Other;
-
-