Model Number ZEPHYR 4.0-LP EBV |
Device Problem
Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problem
Pneumothorax (2012)
|
Event Date 10/21/2019 |
Event Type
Injury
|
Manufacturer Narrative
|
Pneumothorax is the most common side effect associated with the zephyr valve treatment (criner et al.A multicenter randomized controlled trial of zephyr endobronchial valve treatment in heterogeneous emphysema (liberate).Am j respir crit care med.2018; 198 (9): 1151-1164).Targeted lobar deflation likely causes inflation of the ipsilateral lobe, which can result in a tear of the already compromised parenchymal tissue of the emphysematous ipsilateral lobe, resulting in a pneumothorax (criner et al.A multicenter randomized controlled trial of zephyr endobronchial valve treatment in heterogeneous emphysema (liberate).Am j respir crit care med.2018; 198 (9): 1151-1164).In the (b)(6) study ((b)(6) clinical study used to support pma p180002's approval), 26.6% of the zephyr valve subjects experienced a pneumothorax in the treatment period (less than or equal to 45 days).These were managed using standard of care procedures as per previously published guidelines (valipour, arschang, et al.Respiration 87.6 (2014): 513-521).In 17.4% of the events, the pneumothorax resolved without any additional intervention with subjects under careful observation.In over half the events (56.5%), the pneumothorax was managed with a chest-tube only.An additional 13% of the events were managed with a chest-tube and the temporary removal of one or more valves, while another 13% of the events were managed with a chest-tube and removal of all the implanted valves.Upon successful resolution of the pneumothorax, removed valves can be replaced.Patients that experienced a pneumothorax experienced clinical benefits of the zephyr valve treatment that were similar to the benefits experienced by patients who did not have a pneumothorax.The zephyr ebv system ifu and pulmonx training program both specifically reference pneumothorax as a known side effect of this procedure and the published guidelines (valipour, arschang, et al."expert statement: pneumothorax associated with endoscopic valve therapy for emphysema-potential mechanisms, treatment algorithm, and case examples." respiration 87.6 (2014): 513-521).The reported event aligns with the experience observed in the (b)(6)clinical study and is an expected side effect to the zephyr valve treatment.
|
|
Event Description
|
A chartis assessment was performed in the left lower lobe (lll) of the patient and gave a negative collateral ventilation reading.On (b)(6) 2019, patient underwent bronchoscopic procedure and six zephyr endobronchial valves (one 4.0 ebv, two 4.0-lp ebvs, one 5.5 ebv, and two 5.5-lp ebvs) were placed in the lll based on ct.A chest tube was placed immediately because the physician wants to preemptively place chest tubes in his zephyr valve patients until the hospital has adequate processes in place to handle chest tube placements during the 3-day post-procedure inpatient stay.The patient experienced a pneumothorax later in the day.On (b)(6) 2019, the lung expanded, but an air leak remained.On (b)(6) 2019, two zephyr valves (one 5.5 ebv and one 5.5-lp ebv) were removed, and the leak resolved the next day.On (b)(6) 2019, the chest tube was removed.On (b)(6) 2019, the patient was discharged from hospital.
|
|
Search Alerts/Recalls
|
|