MAUDE Adverse Event Report: BOSTON SCIENTIFIC CORPORATION FLEXTOME CUTTING BALLOON; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BOSTON SCIENTIFIC CORPORATION FLEXTOME CUTTING BALLOON; CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS Back to Search Results
Model Number 3822
Device Problem Inflation Problem (1310)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 09/12/2019
Event Type  malfunction  
Manufacturer Narrative
Device evaluated by manufacturer: the device was returned for analysis.A visual examination identified that there was blood in the balloon material which suggests that there is a leak in the device.The returned device was attached to an encore inflation unit and positive pressure was applied in an attempt to inflate the balloon.The balloon could not be inflated due to the presence of solidified blood that was present within the inflation lumen.The device was soaked in a water bath at a temperature of 37 degrees celsius to help soften the blood before further inflation attempts were made.The device was removed from the bath and the balloon was again attached to an inflation device, but the balloon would not inflate.A further microscopic examination detected a balloon hole/tear detected 2mm proximal of the proximal markerband.An examination of the balloon material and markerbands identified no issues which could potentially have contributed to this complaint.A visual and tactile examination of the hypotube was completed.No damage or any issues were noted with the hypotube that could have contributed to the complaint incident.A visual and tactile examination identified no issues with the shaft which may have potentially contributed to the complaint incident.No damage or any issues were noted with the polymer extrusion shaft that could have contributed to the complaint incident.A visual and microscopic examination of the markerbands was completed.There was no burrs or uneven edges observed on the markerbands.No damage or any issues were noted with the markerbands that could have contributed to the complaint incident.No damage or any issues were noted with the tip that could have contributed to the complaint incident.A visual and microscopic examination observed no damage to the tip or blades.All blades were intact and fully bonded to the balloon surface.No damage or any issues were noted with the blades that could have contributed to the complaint incident.No other issues were identified during the product analysis.
 
Event Description
Reportable based on device analysis completed on 13nov2019.It was reported that the balloon was damaged.The severely stenosed target lesion was located in the severely tortuous and severely calcified left anterior descending artery.During the procedure, the balloon was delivered to the distal end of the lesion by guidezilla guide extension catheter; however, it was noted that the balloon could not be filled at 6atm.Furthermore, it was found that the balloon was damaged.The device was completely removed from the patient without any intervention and the procedure was completed with another of the same device.There were no complications reported and the patient's condition was stable post procedure.However, device analysis revealed a balloon hole/tear detected 2mm proximal of the proximal markerbands.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLEXTOME CUTTING BALLOON
Type of Device
CATHETERS, TRANSLUMINAL CORONARY ANGIOPLASTY, PERCUTANEOUS
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
two scimed place
maple grove MN 55311
Manufacturer (Section G)
BOSTON SCIENTIFIC IRELAND LIMITED
ballybrit business park
galway
EI  
Manufacturer Contact
jay johnson
two scimed place
maple grove, MN 55311
7634942574
MDR Report Key9390537
MDR Text Key174388288
Report Number2134265-2019-14616
Device Sequence Number1
Product Code NWX
Combination Product (y/n)N
Reporter Country CodeCH
PMA/PMN Number
P950020
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Reporter Occupation Physician
Type of Report Initial
Report Date 11/28/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received11/28/2019
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/11/2022
Device Model Number3822
Device Catalogue Number3822
Device Lot Number0023334405
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer10/22/2019
Is the Reporter a Health Professional? Yes
Date Manufacturer Received11/13/2019
Was Device Evaluated by Manufacturer? Yes
Date Device Manufactured02/12/2019
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Age68 YR
Patient Weight65
-
-