• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: DEPUY ORTHOPAEDICS INC US UNKNOWN HIP FEMORAL HEAD

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

DEPUY ORTHOPAEDICS INC US UNKNOWN HIP FEMORAL HEAD Back to Search Results
Catalog Number UNK HIP FEMORAL HEAD
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Death (1802); Heart Failure (2206)
Event Date 09/03/2008
Event Type  Death  
Manufacturer Narrative
Product complaint # (b)(4).Report source is a literature article.There is limited information regarding the reported death.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
The literature article entitled, "penetration of a metallic femoral head through the acetabular shell" written by robert a.Sherman, md, and timothy a.Damron, md published by the journal of arthroplasty vol.24 no.7 2009 accepted by publisher 3 september 2008 was reviewed.The article purpose was to report on one case of a (b)(6) man who underwent l tha implanted with depuy profile stem and acetabular cup system.Medical history includes coronary artery disease, hypertension, osteoarthritis, dysrhythmia and trigeminal neuralgias.Eighteen years post implantation he presented painful hip rom and a shortened, externally rotated left lower extremity.Radiographs revealed the appearance of a traditional dislocation but the head/neck was noted to be overlying the acetabular component on both anteroposterior and lateral views so no attempts at closed reduction.Revision operation was performed and intraoperative findings included metallosis, eroded poly liner and eroded metal shell, osteolysis with supra-acetabular bone surrounded by blackened metal debris.All components including stem were removed and replaced.Cancellous allograft utilized in acetabulum and allograft struts utilized in femur in conjunction with cable plate and wiring.It was estimated a 1300 ml blood loss.Patient was placed in icu and within 12 hours his medical condition worsened necessitating re-intubation and immediately followed by catastrophic cardiac injury and died.Depuy products utilized: profile stem, metal head, metal cup, poly liner.Adverse events: death, cardiac failure, dislocation, revision, foreign body reaction (stemming from liner, cup and head as the liner was worn and cup and head resulted in metal debris with note of implant errosion), major bleed, pain.
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provision of 21 cfr, part 803.The report may be based on the information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.H10 additional narrative: product complaint # (b)(4).Investigation summary no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed, and the investigation will be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL HEAD
Type of Device
HIP FEMORAL HEAD
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key9427096
MDR Text Key169552757
Report Number1818910-2019-121581
Device Sequence Number1
Product Code KWY
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,literatur
Type of Report Initial,Followup
Report Date 11/15/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL HEAD
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 11/15/2019
Initial Date FDA Received12/06/2019
Supplement Dates Manufacturer Received01/13/2020
Supplement Dates FDA Received01/14/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Death;
-
-