Model Number 2420-0007
Device Problems False Alarm (1013); Stretched (1601); Obstruction of Flow (2423); Material Deformation (2976)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/02/2019
Event Type  malfunction  
Manufacturer Narrative
Although requested, product has not been received.A follow up report will be submitted with failure investigation results should the product be received for evaluation.
 
Event Description
It was reported that tubing ballooned while priming and received an occlusion alarm.There was no patient harm.
 
Manufacturer Narrative
Additional information added; h.6.(device code).The customer¿s report of balloon in the silicone segment was confirmed per photo received by the customer.Photo shows a bulge/balloon in the silicone segment tubing near the upper fitment.Prior complaints for this same failure mode determined that the ballooning is caused by excess pressure within the silicone tubing segment.The root cause for the source of the excessive pressure is unknown.
 
Event Description
It was reported that tubing ballooned while priming and received an occlusion alarm.Picture provided by the customer shows a "bulging" in the silicone segment.It was further confirmed during follow up, that there was no patient harm as a result of this event.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ALARIS PUMP MODULE ADMINISTRATION SET
Type of Device
SET, ADMINISTRATION, INFUSION
Manufacturer (Section D)
CAREFUSION
10020 pacific mesa blvd
san diego CA 92121 4386
MDR Report Key9511964
MDR Text Key177017134
Report Number9616066-2019-03676
Device Sequence Number1
Product Code FPA
UDI-Device Identifier07613203021012
UDI-Public7613203021012
Combination Product (y/n)N
PMA/PMN Number
K944320
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,health
Type of Report Initial,Followup
Report Date 12/02/2019
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number2420-0007
Device Catalogue Number2420-0007
Was Device Available for Evaluation? No
Initial Date Manufacturer Received Not provided
Initial Date FDA Received12/23/2019
Supplement Dates Manufacturer ReceivedNot provided
Supplement Dates FDA Received01/30/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-