TELEFLEX MEDICAL AUTO ENDO5 ML; CLIP, IMPLANTABLE Back to Search Results
Catalog Number AE05ML
Device Problem Activation, Positioning or Separation Problem (2906)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 12/23/2019
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
 
Event Description
It was reported that the first clip failed to load properly.
 
Event Description
It was reported that the first clip failed to load properly.
 
Manufacturer Narrative
(b)(4).Per dhr the product auto endo5 ml lot # 73m1800266 was manufactured on (b)(6) 2018 a total of 288 pieces.Lot was released on (b)(6) 2018.Dhr investigation did not show issues related to complaint.The customer returned one unit ae05ml autoend05 ml for investigation.The returned sample was visually examined with and without mag nification.Visual examination of the returned device revealed that the sample was returned with its trigger partially engaged and with the rotation tab bent.A clip was stuck in the bent rotation tab.A closed clip was returned loose.The sample appears used as there is biological material present on the device.Reference file anp1900074696 for investigation photos.First, the clip stuck in the bent rotation tab was manually removed.Upon removal of the clip, the next clip protruded from the channel.The next clip was also removed and the trigger cycle was completed.The following clip was out of position in the channel.Functional inspection was then performed on the returned sample by attempting to engage the trigger using hand pressure.Upon engagement of the trigger, an audible ratchet sound could be heard indicating that the internal ratchet ears are intact.The following clip was unable to load properly into the jaws.The sample was disassembled to inspect the internal components.It was found that the clips were out of position and stacking on one another in the channel.The sample was received with 8 clips remaining including the clip that was stuck in the bent rotation tab, indicating that 7 clips including the loose closed clip were fired by the end user.The clip stacking prevented the clips from loading properly into the jaws.It could not be determined exactly how or when the clips became out of position.A capa has been opened to further investigate this issue.Reference file anp1900074696 for investigation photos.The ifu for this product, l06072, was reviewed as a part of this complaint investigation.The ifu for this product states, "mishandling of appliers may result in improper load and/or closure of the ligating clip." the clip stacking prevented the clips from loading properly into the jaws.It could not be determined exactly how or when the clips became out of position.A capa has been opened to further investigate this issue.The reported complaint of "clips not loading properly" was confirmed based upon the sample received.One device was returned with the rotation tab bent.A clip was stuck in the bent rotation tab.A closed clip was also returned loose.Upon functional inspection, the clips were unable to load properly.The sample was disassembled and it was found that the clips were out of position and stacking on one another.The clip stacking prevented the clips from loading properly into the jaws.Although the reported complaint issue was confirmed based on functional testing, it could not be determined exactly how or when the clips became out of position.A capa has been opened to further investigate this issue.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AUTO ENDO5 ML
Type of Device
CLIP, IMPLANTABLE
Manufacturer (Section D)
TELEFLEX MEDICAL
morrisville NC
MDR Report Key9571096
MDR Text Key175839041
Report Number3003898360-2020-00115
Device Sequence Number1
Product Code FZP
Combination Product (y/n)N
PMA/PMN Number
K152081
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Type of Report Initial,Followup
Report Date 01/09/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/09/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberAE05ML
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer01/17/2020
Date Manufacturer Received02/24/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-