Catalog Number UNK HIP FEMORAL STEM
Device Problems Loss of or Failure to Bond (1068); Loss of Osseointegration (2408)
Patient Problems Bone Fracture(s) (1870); Pain (1994); No Code Available (3191)
Event Date 07/04/2011
Event Type  Injury  
Manufacturer Narrative
(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.(b)(4).
 
Event Description
"literature article entitled, ¿femoral revision surgery with impaction bone grafting¿ by b.L.E.F.Ten have, et al, published by the journal of bone and joint surgery (2012), vol.94-b, no.5, pp.615-618, was reviewed.The purpose of this prospective study was to evaluate the long-term clinical and radiological outcomes of revision of the femoral component of a total hip replacement using impaction bone grafting in 29 patients between september 1992 and september 1995.The article studies the outcomes of a competitor stem and head implanted during revision surgery.This complaint will capture the depuy components that were explanted during the revision surgery.Revised depuy products: 10 charnley stems and 3 minneapolis stems.The stems were paired with depuy femoral heads.Reasons for revision: aseptic loosening, pain, and periprosthetic fracture.The authors do not identify the reasons for revision by device manufacturer.The actual number of depuy stems associated with the following reasons for revision are unknown.There were no reported product problems with the femoral heads.Captured in this complaint: 13 stems: implant loosening of an unknown interface; fracture, pain, surgical intervention, medical device removal.13 femoral heads: no reported product problem; pain, surgical intervention, and medical device removal.".
 
Manufacturer Narrative
Depuy synthes is submitting this report pursuant to the provision of 21 cfr, part 803.The report may be based on the information which depuy synthes has not been able to investigate or verify prior to the required reporting date.This report does not reflect a conclusion by fda, depuy synthes or its employees that the report constitutes an admission that the device, depuy synthes, or its employees caused or contributed to the potential event described in this report.Product complaint # (b)(4).Investigation summary: root cause undetermined.Depuy synthes considers the investigation closed at this time.Should additional information be received, the information will be reviewed and the investigation may be re-opened as necessary.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
UNKNOWN HIP FEMORAL STEM
Type of Device
HIP FEMORAL STEM
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key9601441
MDR Text Key188186266
Report Number1818910-2020-02095
Device Sequence Number1
Product Code KXA
Combination Product (y/n)N
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,l
Type of Report Initial,Followup
Report Date 01/03/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue NumberUNK HIP FEMORAL STEM
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 01/03/2020
Initial Date FDA Received01/17/2020
Supplement Dates Manufacturer Received01/29/2020
Supplement Dates FDA Received02/03/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
-
-