Catalog Number 500101
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Encephalopathy (1833); Neurological Deficit/Dysfunction (1982)
Event Type  Death  
Manufacturer Narrative
The syncardia 70cc temporary total artificial heart (tah-t) is an implantable pulsatile biventricular replacement device that replaces a patient's native ventricles and valves and pumps blood to both the pulmonary and systemic circulation systems.The syncardia 70cc tah-t is indicated for use as a bridge to transplantation in cardiac transplant-eligible candidates at risk of imminent death from biventricular failure.The syncardia tah-t system is intended for use inside and outside the hospital.Investigation summary: intermacs patient registry data collected from january 1, 2019 through june 30, 2019 regarding adverse events was reviewed.Patients were de-identified therefore a one-to-one correlation could not be made between the patient and the lot number of the implanted tah-t.With a review of the available information, there is no evidence of a device malfunction or performance issues that would impact the reported events.Possible clinical factors that may have contributed to these events include the patients pre-existing history and related comorbidities, the progression of their underlying disease, issues related to the therapeutic use of anticoagulants, antiplatelet medications and the patient's complex post-operative course.There are possible patient, pharmacological and procedural factors that may have contributed to these events.This device is used for treatment, not diagnosis.(b)(4).
 
Event Description
While supported by a tah-t, the patient has experienced the following adverse events as defined by intermacs: 10 days post implant: neurological dysfunction: cva i location: lh: parietal i severity: speech deficit.81 days post implant - device malfunction and/or pump thrombosis.As of june 30, 2019 it was reported that the patient was still supported by a tah-t.
 
Event Description
Since the last reporting period, the patient experienced the following adverse events as defined by intermacs: 143 days post implant- device malfunction and/or pump thrombosis; 410 days post implant- device malfunction and/or pump thrombosis; 410 days post implant- neurological dysfunction - encephalopathy; 410 days post implant- other sae.The patient subsequently expired with a cause of death listed as nervous system: neurological dysfunction after 410 days of tah-t support.
 
Manufacturer Narrative
Intermacs patient registry data collected from (b)(6) 2019 through (b)(6) 2020 regarding adverse events was reviewed.Patients were de-identified therefore a one-to-one correlation could not be made between the patient and the lot number of the implanted tah-t.Ce 5519 pt 120036 follow-up report 1.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNCARDIA 70CC TEMPORARY TOTAL ARTIFICIAL HEART (TAH-T)
Type of Device
BIVENTRICULAR REPLACEMENT DEVICE
Manufacturer (Section D)
SYNCARDIA SYSTEMS, LLC
1992 e. silverlake road
tucson AZ 85713
MDR Report Key9671020
MDR Text Key178137702
Report Number3003761017-2020-00015
Device Sequence Number1
Product Code LOZ
Combination Product (y/n)N
PMA/PMN Number
P030011
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type other
Type of Report Initial,Followup
Report Date 04/20/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Catalogue Number500101
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 11/13/2019
Initial Date FDA Received02/05/2020
Supplement Dates Manufacturer Received04/15/2021
Supplement Dates FDA Received04/23/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Death; Other;
Patient Weight94
-
-