Catalog Number 397003-001
Device Problem Image Display Error/Artifact (1304)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 02/13/2020
Event Type  malfunction  
Manufacturer Narrative
The companion hospital cart has been returned to syncardia for evaluation.The results of the evaluation will be provided in a follow-up mdr.(b)(4.
 
Event Description
The syncardia companion hospital cart is a large cart with wheels into which the syncardia companion 2 driver docks.It is intended for use in the hospital during the temporary total artificial heart (tah-t) implant procedure and subsequent recovery.The customer, a syncardia certified hospital, reported that the screen on the hospital cart turned blue while supporting a patient.
 
Manufacturer Narrative
During investigation testing, the customer-reported issue of the blue hospital cart screen was only able to be reproduced when a companion 2 driver was intentionally docked improperly into the hospital cart and missed the docking guide.This prevented proper electrical connection for docking the driver into the cart and caused the cart screen to change to a blue color.The companion 2 driver operator manual states in section 1.2 that the driver docks into the hospital cart by placing the driver straight into the center of the hospital cart so the docking connectors mate.This issue will continue to be monitored and trended as part of the customer experience process.Syncardia has completed its evaluation of this complaint and is closing this file.Ce 5211 follow-up report 1.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SYNCARDIA COMPANION HOSPITAL CART
Type of Device
CART
Manufacturer (Section D)
SYNCARDIA SYSTEMS, LLC
1992 e. silverlake road
tucson, az
MDR Report Key9753042
MDR Text Key181546611
Report Number3003761017-2020-00077
Device Sequence Number1
Product Code LOZ
Combination Product (y/n)N
PMA/PMN Number
P030011
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional,user faci
Type of Report Initial,Followup
Report Date 04/09/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/26/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number397003-001
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/11/2020
Date Manufacturer Received02/13/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age60 YR
-
-