MAUDE Adverse Event Report: TOSOH CORPORATION AIA-900

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

TOSOH CORPORATION AIA-900 Back to Search Results
Model Number AIA-900
Device Problems Incorrect, Inadequate or Imprecise Result or Readings (1535); High Readings (2459)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 03/02/2020
Event Type  malfunction  
Manufacturer Narrative
Submission of this report does not constitute an admission that the manufacturer's product caused or contributed to the event.A 13-month lot review for similar complaints was performed for test cup lot j7141a3 and for calibrator lot jy33137.There were no complaints found during the searched period.A 13-month complaint history review and service history review through aware date of event for similar complaints was performed for serial number (b)(4).There were no other similar complaints found during the searched period.The st aia-pack prl analyte application manual states the following: calibration and calibration curve.The calibration curve for the st aia-pack prl is stable for up to 90 days.Calibration stability is monitored by quality control performance and is dependent upon proper reagent handling and aia system maintenance according to the manufacturer's instructions.Recalibration may be necessary more frequently if controls are out of the established range for this assay or if certain service procedures are performed (e.G.Temperature adjustment, sampling mechanism changes, or detector lamp adjustment or change).For further information regarding instrument operation, consult the aia system operator's manual.Evaluation of results.Quality control.In order to monitor and evaluate the precision of the analytical performance, it is recommended that commercially available control samples be assayed daily.The minimum recommendations for the frequency of running internal control material are: after calibration, two levels of controls are run in order to accept the calibration curve.The two levels of controls are also repeated after calibration when certain service procedures are performed (e.G.Temperature adjustment, sampling mechanism changes, maintenance of the wash probe or detector lamp adjustment or change).After daily maintenance, at least two levels of the control should be run in order to verify the overall performance of the tosoh aia system analyzers.If one or more control sample value(s) is out of the acceptable range, it will be necessary to investigate the validity of the calibration curve before reporting patient results.Limitations of the procedure.For diagnostic purposes, the results obtained from this assay should be used in conjunction with other data (e.G., symptoms, results of other tests, clinical impressions, therapy, etc.).Using st aia-pack prl, the highest concentration of prolactin measurable without dilution is 200 ng/ml, and the lowest measurable concentration is 1.0 ng/ml (assay sensitivity).Although the approximate value of the highest calibrator is 100 ng/ml, the exact concentration may be slightly different.The assay specification, assay range high, should be defined as the upper limit of the assay range, 200 ng/ml.Certain medications may interfere with assay performance.Specimens from patients taking medicines and/or medical treatment may show erroneous results.All results should be interpreted with respect to the clinical picture of the patient.The most probable cause of the reported event is unknown.
 
Event Description
A customer reported getting out of range high quality control (qc) result for prolactin (prl) on the aia-900 instrument.The customer is running prl test cup lot j7141a3 and calibrator lot jy33137.Customer stated calibration was completed several times; results will come into range then be out the next day.Technical support specialist (tss) sent mac controls and another lot of calibration to the customer.After recalibration, customer reported all results are within acceptable range.There was no indication of any patient intervention or adverse health consequences due to the delay in reporting of patient results.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AIA-900
Type of Device
AIA-900
Manufacturer (Section D)
TOSOH CORPORATION
shiba-koen first building
3-8-2 shiba
minato-ku, 10586 23
JA  1058623
Manufacturer (Section G)
TOSOH CORPORATION
shiba-koen first building
3-8-2 shiba
minato-ku, 10586 23
JA   1058623
Manufacturer Contact
bernadette oconnell
shiba-koen first building
3-8-2 shiba
minato-ku, tokyo 10586-23
JA   1058623
MDR Report Key9908379
MDR Text Key261057140
Report Number8031673-2020-00088
Device Sequence Number1
Product Code KHO
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K971103
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type health professional
Reporter Occupation Other
Type of Report Initial
Report Date 03/31/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberAIA-900
Device Catalogue Number022930111
Was Device Available for Evaluation? Yes
Initial Date Manufacturer Received 03/02/2020
Initial Date FDA Received03/31/2020
Was Device Evaluated by Manufacturer? No
Date Device Manufactured05/01/2018
Is the Device Single Use? No
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Reuse
Patient Sequence Number1
-
-