Model Number G156
Device Problems Failure to Capture (1081); Off-Label Use (1494)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 01/15/2020
Event Type  malfunction  
Manufacturer Narrative
As no further information concerning this report is expected, our investigation is complete.This investigation will be updated should further information be provided.
 
Event Description
It was reported that this patient underwent a revision procedure to due improved ejection fraction, severe tricuspid regurgitation and no capture in the right ventricle (rv).A left ventricular (lv) lead was implanted and was placed in the rv port and positioned in the middle cardiac vein.This lead will be used just for sensing as no capture could be obtained at maximum device outputs.Therefore, this system cannot be programmed to vvi configuration.A boston scientific technical services consultant documented the clinical observations and programming information and informed the representative that the configuration of this system is considered off label.No adverse patient effects were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
DYNAGEN X4 CRT-D
Type of Device
DEFIBRILLATOR, AUTOMATIC IMPLANTABLE CARDIOVERTER, WITH CRT-D
Manufacturer (Section D)
BOSTON SCIENTIFIC CORPORATION
4100 hamline avenue north
saint paul MN 55112
Manufacturer (Section G)
BOSTON SCIENTIFIC CORPORATION
cashel road
clonmel
EI  
Manufacturer Contact
timothy degroot
4100 hamline avenue north
saint paul, MN 55112
6515826168
MDR Report Key9922477
MDR Text Key186377589
Report Number2124215-2020-03938
Device Sequence Number1
Product Code NIK
UDI-Device Identifier00802526534669
UDI-Public00802526534669
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
P010012/S341
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative
Reporter Occupation Other
Type of Report Initial
Report Date 04/03/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Lay User/Patient
Device Expiration Date06/20/2020
Device Model NumberG156
Device Catalogue NumberG156
Device Lot Number380340
Was Device Available for Evaluation? No
Initial Date Manufacturer Received 01/15/2020
Initial Date FDA Received04/03/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured07/19/2018
Is the Device Single Use? Yes
Type of Device Usage Initial
Patient Sequence Number1
Patient Age84 YR
-
-