• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: IHEALTH LABS INC. IHEALTH COVID-19 ANTIGEN RAPID TEST; CORONAVIRUS ANTIGEN DETECTION TEST SYSTEM

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

IHEALTH LABS INC. IHEALTH COVID-19 ANTIGEN RAPID TEST; CORONAVIRUS ANTIGEN DETECTION TEST SYSTEM Back to Search Results
Device Problems Product Quality Problem (1506); Incorrect, Inadequate or Imprecise Result or Readings (1535)
Patient Problem No Clinical Signs, Symptoms or Conditions (4582)
Event Date 10/24/2022
Event Type  malfunction  
Event Description
Multiple problems with ihealth covid-19 antigen rapid test kits--today's testing is an example.Both of 2 kits in one box in lot no.(10):222c020210 were faulty, unusable, due to an extremely faint positive control.This is about the 8th of these tests that i have found to be faulty due to incorrect control, not all in the same lot (expiries july to aug 22), not always both kits in same box of 2, and also in one box of 2 kits, only 1 kit was present (an extra copy of instructions had been inserted instead).This is not user error: i am a medical professional, and the fluid volume in the tube was correct (some kits have prefilled tubes, some must be filled by user--both have had incorrect controls), the drops used were correct and correctly administered on the kit and fluid diffused correctly to the end of the window (you can see it as a slight color change rolling across the test window).The kits have been within their extended expiry.Very poor quality control by manufacturer.No one was harmed, because testing was repeated, but to have to test 3 times in rapid succession to obtain a valid result is not acceptable, and of course the unusable kits were purchased (in this case, by federal government -- were part of mailed out kits -- or by local government, which distributes them in libraries).Fda safety report id# (b)(4).
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
IHEALTH COVID-19 ANTIGEN RAPID TEST
Type of Device
CORONAVIRUS ANTIGEN DETECTION TEST SYSTEM
Manufacturer (Section D)
IHEALTH LABS INC.
MDR Report Key15673241
MDR Text Key302494249
Report NumberMW5112835
Device Sequence Number6
Product Code QKP
Combination Product (y/n)N
Reporter Country CodeUS
Number of Events Reported1
Summary Report (Y/N)N
Report Source Voluntary
Reporter Occupation Patient
Type of Report Initial
Report Date 10/24/2022
8 Devices were Involved in the Event: 1   2   3   4   5   6   7   8  
1 Patient was Involved in the Event
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Initial Date Manufacturer Received Not provided
Initial Date FDA Received10/25/2022
Patient Sequence Number1
-
-