MAUDE Adverse Event Report: BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. CONNECTA Q-SYTES WHT; STOPCOCK

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. CONNECTA Q-SYTES WHT; STOPCOCK Back to Search Results
Catalog Number 394501
Device Problems Leak/Splash (1354); Device Contamination with Chemical or Other Material (2944)
Patient Problems Emotional Changes (1831); Low Oxygen Saturation (2477); Missed Dose (2561)
Event Date 04/24/2020
Event Type  Injury  
Manufacturer Narrative
Multiple lot numbers were provided and it is not known which is associated with the defective product.The information for each lot number is as follows: medical device lot #: 9246765, medical device expiration date: 08-31-2022, device manufacture date: 09-27-2019, medical device lot #: 9116509, medical device expiration date: 03-31-2022, device manufacture date: 05-06-2019.Investigation summary: a device history record review was performed for the two possible provided lot numbers; 9246765 and 9116509.The review did not reveal any detected quality issues during the production process of either lot number that could have contributed to this reported incident and all inspections were found to be within specification.To aid in the investigation of this issue, three picture samples were received for evaluation by our quality engineer team.Through examination of the pictures, luer-lok damage was observed.The potential causes for luer-lok detachment include incorrect assembly within the manufacturing facility and excess silicone presence.It is also possible that the detachment resulted from incorrect use.Based on the evaluation of the picture samples alone, the exact cause could not be determined.In response to this incident, a quality alert was issued to all related manufacturing personnel, in an attempt to increase awareness for this potential defect.Investigation conclusion: bd was able to confirm the customer¿s indicated failure mode in the photos provided.The potential causes for luer lock detachment is a wrong assembly (in station 03) or the silicon presence on port a (as consequence of excess of silicone in station 06).It is recommended send unused samples to perform a deeper investigation.The maintenance records were reviewed and during the manufacture of this both lots no adjustments were performed that contributes to this failure mode.Quality records have been consulted for tracking and trending purposes but issues like this are not detected which means pretty low occurrence.During the manufacturing were taken samples and tested by collar nut removal force lsl = 35n.Material 394501 & batch 9116509.160 samples were taken and tested per collar nut removal force all the samples passed above the specification.Material 394501 & batch 9246765.148 samples were taken and tested per collar nut removal force all the samples passed above the specification we will keep monitoring the manufacturing process and in case any emerging trend is detected, further actions will be taken if necessary.Process (b)(4) were reviewed and there are proper controls in place to detect product malfunctions.Root cause description: based on investigation results to date, probable root causes can be associated to station 03 (wrong assembly of luer) or incorrect customer use.Rationale: no capa based on an evaluation of severity and frequency it was determined that no corrective action is required at this time.
 
Event Description
It was reported that an unspecified number of connecta q-sytes wht experienced device damage/deformation while still considered operable.Product defect was noted during use.The product defect resulted in a serious injury in the form of a missed dosage which caused agitation, respiratory distress, and desaturation.It has not been specified whether medical intervention was applied as a result.The following information was provided by the initial reporter: sedated intubated patient with a left jugular three-way central line.Patient was agitated and desaturated at time of injury.Valve positioned on the distal ktc line according to the service protocol, sedation line of the intubated patient.Fluid-soaked valve cover.After examination, liquid corresponding to propofol.Luer lock ring of the valve broken making the device unsealable.The patient does not receive the prescribed dose of sedation, resulting in agitation, respiratory distress and desaturation.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
CONNECTA Q-SYTES WHT
Type of Device
STOPCOCK
Manufacturer (Section D)
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
periferico luis donaldo
colosio no. 579
nogales
MX 
Manufacturer (Section G)
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
periferico luis donaldo
colosio no. 579
nogales
MX  
Manufacturer Contact
brett wilko
9450 south state street
sandy, UT 84070
8015652341
MDR Report Key10071370
MDR Text Key198896883
Report Number9610847-2020-00155
Device Sequence Number1
Product Code FMG
Combination Product (y/n)N
Reporter Country CodeFR
PMA/PMN Number
NA
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,other,user facility
Reporter Occupation Other Health Care Professional
Type of Report Initial
Report Date 04/30/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received05/19/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? Yes
Device Operator Other
Device Catalogue Number394501
Device Lot NumberUNKNOWN
Was Device Available for Evaluation? No
Is the Reporter a Health Professional? Yes
Date Manufacturer Received04/30/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Patient Outcome(s) Other;
-
-