ROCHE DIAGNOSTICS ELECSYS ANTI-CCP IMMUNOASSAY; ANTIBODIES, ANTI-CYCLIC CITRULLINATED PEPTIDE (CCP) Back to Search Results
Catalog Number 05031656190
Device Problem Non Reproducible Results (4029)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/25/2020
Event Type  malfunction  
Manufacturer Narrative
This event occurred in (b)(6).
 
Event Description
The initial reporter received a questionable elecsys anti-ccp immunoassay result for one patient tested on a cobas 6000 e 601 module.The initial result was reported outside the laboratory to a clinician.The clinician was alerted of the questionable result due to the result not matching the patient's clinical picture and rheumatoid factor results.The patient's serum sample was tested for confirmation.The patient¿s anti-ccp result with a plasma sample was "weak positive." the patient¿s anti-ccp result with a serum sample was "negative" (<7 iu/ml).The patient's serum result was determined correct.The e 601 module serial number is (b)(4).
 
Manufacturer Narrative
The customer's calibration and qc were acceptable.The investigation discovered patterns of discrepant results between serum and plasma samples from the same blood draw of a given patient: negative results or results below the cutoff value on serum samples and positive results on plasma samples.Also, the concentrations obtained from plasma samples are dependent on the reagent lots used for testing.Further investigations were conducted and the investigation could not identify the root cause.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ELECSYS ANTI-CCP IMMUNOASSAY
Type of Device
ANTIBODIES, ANTI-CYCLIC CITRULLINATED PEPTIDE (CCP)
Manufacturer (Section D)
ROCHE DIAGNOSTICS
9115 hague road
indianapolis IN 46250 0457
MDR Report Key10123507
MDR Text Key203839254
Report Number1823260-2020-01371
Device Sequence Number1
Product Code NHX
Combination Product (y/n)N
PMA/PMN Number
K081338
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional,u
Type of Report Initial,Followup
Report Date 08/12/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/05/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Catalogue Number05031656190
Device Lot NumberASKU
Was Device Available for Evaluation? Yes
Date Manufacturer Received05/11/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-