CORDIS CORPORATION SI AVANTI+ 6F STD W/GW NO OBT; DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION Back to Search Results
Model Number 504606X
Device Problems Device Contamination with Chemical or Other Material (2944); Manufacturing, Packaging or Shipping Problem (2975)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 05/12/2020
Event Type  malfunction  
Manufacturer Narrative
This device is not available for testing and evaluation.The product was not returned for analysis.A review of the manufacturing documentation associated with this lot# 17837060 presented no issues during the manufacturing process that can be related to the reported complaint.Additional information is pending and will be submitted within 30 days upon receipt.
 
Event Description
As reported, it was noted that there are drops of fluid ¿insight¿ the sterile package of a 6f avanti plus standard (std) sheath introducer.It is noted that it is a condense water and it is mostly the explanation.There was no reported patient injury.The device will not be returned for evaluation.An image has been attached for review.
 
Event Description
As reported, it was noted that there are drops of fluid inside the sterile package of a 5f avanti plus standard (std) sheath introducer.It is noted that it is a condense water and it is mostly the explanation.There was no reported patient injury.No damages were noted to packaging of the device.The event did not cause a clinically relevant increase in the duration of the procedure.The event did not cause a condition that requires hospitalization or significant prolongation of existing hospitalization.The device will not be returned for evaluation.An image has been attached for review.
 
Manufacturer Narrative
After further review of additional information received the following sections have been updated accordingly: b5,g4, g7, h1, h2, h3 and h10.This device is available for analysis but the engineering report is not yet available.However, it will be submitted within 30 days upon receipt.
 
Manufacturer Narrative
As reported, it was noted that there are drops of fluid inside the sterile package of a 5f avanti plus standard (std) sheath introducer.It is noted that it is a condense water and it is mostly the explanation.There was no reported patient injury.No damages were noted to packaging of the device.The event did not cause a clinically relevant increase in the duration of the procedure.The event did not cause a condition that requires hospitalization or significant prolongation of existing hospitalization.The product was returned for analysis.A non-sterile units of product si avanti+ 6f std w/gw no obt were received for analysis inside a plastic bag.Per visual analysis, an oily substance was observed on the surface of the csi valve.No other visible anomalies were observed during the analysis.Per ir spectra obtained from the seemingly foreign material observed in valve of si avanti+ 6f std units has a polyethylene composition with mdx fluid, since characteristic ir bands found on spectrum corresponding to these materials.A product history record (phr) review of lot 17837060 revealed no anomalies or non-conformances during the manufacturing and inspection processes that can be associated with the reported event.The reported ¿packaging/pouch/box ¿ foreign material in sterile package¿ was not confirmed during analysis of the returned device.The exact cause of the reported event could not be conclusively determined.It should be noted that medical fluid is applied to the device during the manufacturing process.Medical fluid is inherent to the manufacturing process of the device and not considered foreign.However, as the customer is not aware of the manufacturing process of the unit, this material could appear as foreign, and the presence of the substance was confirmed.It should be noted that the medical fluid is biocompatible, and these devices are safe to be used with the fluid.The medical fluid is intended to lubricate the interaction between the vessel dilator and the gasket component.According to the instructions for use, which is not intended as a mitigation of risk, ¿do not use if package is open or damaged.¿ standard clinical practice calls for inspection of the device and packaging prior to use in the patient.If the user notes anything unusual, they are urged to discontinue use of the device and exchange for another.Neither the phr review, the product analysis suggest that the event experienced by the customer could be related to the manufacturing process; therefore, no corrective/preventive action will be taken at this time.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SI AVANTI+ 6F STD W/GW NO OBT
Type of Device
DILATOR, VESSEL, FOR PERCUTANEOUS CATHETERIZATION
Manufacturer (Section D)
CORDIS CORPORATION
14201 nw 60 avenue
miami lakes FL 33014
MDR Report Key10140699
MDR Text Key194798210
Report Number9616099-2020-03737
Device Sequence Number1
Product Code DRE
UDI-Device Identifier20705032010051
UDI-Public20705032010051
Combination Product (y/n)N
PMA/PMN Number
K970392
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup,Followup
Report Date 08/06/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received06/10/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date12/31/2021
Device Model Number504606X
Device Catalogue Number504606X
Device Lot Number17837060
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/01/2020
Date Manufacturer Received07/31/2020
Is This a Reprocessed and Reused Single-Use Device? No