Model Number SET ROTAREX®S 6F X 110CM
Device Problems No Flow (2991); No Apparent Adverse Event (3189)
Patient Problem No Known Impact Or Consequence To Patient (2692)
Event Date 06/18/2020
Event Type  malfunction  
Manufacturer Narrative
Evaluation protocol not yet completed.
 
Event Description
Rotarex 6f 110cm was used to treat the thrombosis in the superficial femoral artery.After rinsing, catheter was inserted into the vessel and start aspiration.No blood was found flowing out from the catheter.Withdraw the catheter, flush again and no liquid was found flowing out.Operation was finally completed by another 6f 110 catheter.
 
Manufacturer Narrative
Evaluation summary signed on 08/07/2020 attached.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ROTAREXS 6F 110CM (STRAUB MEDICAL)
Type of Device
ATHERECTOMY CATHETER
Manufacturer (Section D)
STRAUB MEDICAL AG
straubstrasse 12
wangs, sankt gallen 7323
SZ  7323
MDR Report Key10338679
MDR Text Key242645270
Report Number3008439199-2020-00024
Device Sequence Number1
Product Code MCW
UDI-Device Identifier07640142810285
UDI-Public7640142810285
Combination Product (y/n)N
PMA/PMN Number
K172315
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,health profession
Type of Report Initial,Followup
Report Date 06/30/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received07/29/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date01/20/2023
Device Model NumberSET ROTAREX®S 6F X 110CM
Device Catalogue Number80219
Device Lot Number200214
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer07/15/2020
Date Manufacturer Received06/30/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age66 YR
Patient Weight72
-
-