MAUDE Adverse Event Report: EPIDURAL CATHETERIZATION SET; ANESTHESIA CONDUCTION KIT

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

EPIDURAL CATHETERIZATION SET; ANESTHESIA CONDUCTION KIT Back to Search Results
Model Number IPN046311
Device Problem Failure to Advance (2524)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 07/24/2020
Event Type  malfunction  
Manufacturer Narrative
(b)(4).The device has not been returned for investigation.Teleflex will continue to monitor and trend related events.
 
Event Description
It was reported that it was impossible to aspire or push the plunger of the syringe.
 
Manufacturer Narrative
Qn# (b)(4).A device history record review was performed on the lor syringe with no relevant findings.The customer reported it was impossible to push the plunger of the syringe.The customer returned one empty kit with a 10ml plastic lor syringe.The syringe was visually examined with and without magnification.Visual examination of the syringe revealed that the syringe appears typical with no observed defects or anomalies.Functional testing was performed on the returned syringe.The returned lor syringe was compared to a lab inventory syringe by sliding the plunger into the barrel of the syringe.The resistance of the returned lor syringe was comparable to the lab inventory syringe.Leak testing was also performed on the returned lor syringe using the lab leak tester (ref-002902) per the parameters in amrq-000155 rev.6, section 7.2-positive pressure leakage.Water was aspirated into the syringe to the 10ml mark and the syringe was inverted to remove any air from the barrel.The tip of the syringe was then connected to the lab leak tester via tubing and pressure was applied.The syringe was tested at 10psi for 10 seconds.No leaks were detected.The plunger was rotated 45deg and the syringe was once again tested at 10psi for 10 seconds and no leaks were detected.This was performed by rotating the plunger 45deg until the plunger had rotated a full 360deg with no leaks detected.Water was removed from the syringe to the 8ml mark and the syringe was inverted to remove any air from the barrel.The tip of the syringe was then connected to the lab leak tester via tubing and pressure was applied.The syringe was tested at 10psi for 10 seconds with the plunger being rotated 45deg until it had rotated a 360deg with no leaks being detected.Water was removed from the syringe to the 2ml mark and the syringe was inverted to remove any air from the barrel.The tip of the syringe was then connected to the lab leak tester via tubing and pressure was applied.The syringe was tested at 10psi for 10 seconds with the plunger being rotated 45deg until it had rotated a 360deg with no leaks being detected.The luer end of the returned syringe was capped.With the tip sealed, the lor syringe was tested for leaks by pushing the plunger into the barrel.This was performed at 8ml, 5ml, and 2ml by pushing the plunger and rotating 45deg until the plunger had rotated a full 360deg.No leaks or slippage of the plunger occurred.An attempt to remove the plunger from the barrel was performed.The plunger seal snapped back when attempting to remove from the barrel.This was also performed with a lab inventory syringe with the same results.This indicates the plunger seal was creating a vacuum with no issues.A design history review was performed for part # kz-05501-002 as a part of this complaint investigation.Per eco-051699 (released 03-dec-2018), supplier ((b)(4)) made the following changes: kz-05501-002 luer plastic lor syringe: a.Changed plunger material from profax 535 to profax 531 b.Changed to new plunger tool c.Changed to new mold for blue stopper d.Changed molding location for the plunger and the blue stopper as follows.Plunger: from fleimaplastic in germany to gpe, germany - blue stopper: from et, germany to psilkon, germany.These effective changes did impact product design and material.It should be noted, the returned lor syringe was from the new design.A corrective action is not required at this time as there were no functional issues found with the returned sample.The reported complaint of it was impossible to push the plunger of the syringe could not be confirmed based on the sample received.The returned lor syringe when compared to a lab inventory syringe had comparable resistance when sliding the plunger into the barrel of the syringe.The returned lor syringe also passed functional leak testing.A device history record review was performed on the lor syringe with no evidence to suggest a manufacturing related issue.Therefore, based on this, no issues were found with the returned sample.
 
Event Description
It was reported that it was impossible to aspire or push the plunger of the syringe.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EPIDURAL CATHETERIZATION SET
Type of Device
ANESTHESIA CONDUCTION KIT
MDR Report Key10388133
MDR Text Key202399303
Report Number3006425876-2020-00696
Device Sequence Number1
Product Code CAZ
Combination Product (y/n)N
PMA/PMN Number
K103658
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type foreign,health professional
Type of Report Initial,Followup
Report Date 07/24/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received08/10/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Expiration Date02/16/2022
Device Model NumberIPN046311
Device Catalogue NumberJC-05400-B
Device Lot Number71F20B2207
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer08/31/2020
Date Manufacturer Received09/09/2020
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured02/27/2020
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage N
Patient Sequence Number1
-
-