C.R. BARD, INC. (COVINGTON) -1018233 AVAULTA PLUS® BIOSYNTHETIC SUPPORT SYSTEM - ANTERIOR Back to Search Results
Catalog Number 486101
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Abdominal Pain (1685); Asthma (1726); Erosion (1750); Pain (1994); Urinary Tract Infection (2120); Urinary Frequency (2275); Distress (2329); Injury (2348); Disability (2371); Prolapse (2475); Urinary Incontinence (4572); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
Event Type  Injury  
Manufacturer Narrative
The sample was not returned.The finished product met all specifications prior to being released for general distribution.The instructions for use which accompanies all devices currently addresses potential risks associated with surgically implanted materials.The instructions for use states in the adverse events: ¿potential adverse reactions are those typically associated with surgically implantable materials, including hematoma, seroma, mucosal or visceral erosion, infection, inflammation, sensitization, dyspareunia, scarification and contraction, fistula formation, extrusion and recurrence of vaginal wall prolapse.Perforations or lacerations of vessels, nerves, bladder, bowel, rectum, or any viscera may occur during needle passage." (b)(4).
 
Event Description
It was reported by the patient's attorney that as a result of having the product implanted the patient has experienced pain, injury, disability, and impairment.
 
Event Description
N/a.
 
Manufacturer Narrative
Correction: mdr date of awareness.
 
Event Description
Per additional information received on (b)(6) 2021, the patient has experienced pain, urinary tract infections, mesh erosion, pelvic and groin pain, emotional and mental distress, stabbing pain in vagina, cystocele, enterocele, bladder infections, urinary incontinence, uterine prolapse, vaginal dryness, overactive bladder, nocturia, vaginal prolapse, bulge sensation, grade 1-2 distal rectocele, grade 2 vault prolapse, urinary frequency and required additional surgical and non-surgical interventions.
 
Manufacturer Narrative
1750, 2120, 1930, 2475="l" 2329, 1928, 2275="nl".H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Manufacturer Narrative
1685="l".2564, 2519 ="nl".H11:section a through f - the information provided by bd represents all of the known information at this time.Despite good faith efforts to obtain additional information, the complainant / reporter was unable or unwilling to provide any further patient, product, or procedural details to bd.
 
Event Description
As per additional information received via medical records on 08jan2024, the patient had experienced vaginal pain, stabbing injuries in the vagina, urinary tract infection, mesh erosion, pelvic and groin pain, emotional and mental distress, cystocele, enterocele, bladder infections, urinary incontinence, uterine prolapse, vaginal dryness, overactive bladder allergies, mild asthma and required additional surgical and non- surgical treatment.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
AVAULTA PLUS® BIOSYNTHETIC SUPPORT SYSTEM - ANTERIOR
Type of Device
AVAULTA PLUS® BIOSYNTHETIC SUPPORT SYSTEM - ANTERIOR
Manufacturer (Section D)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
Manufacturer (Section G)
C.R. BARD, INC. (COVINGTON) -1018233
8195 industrial blvd
covington GA 30014
Manufacturer Contact
xeeroy rada
8195 industrial blvd
covington, GA 30014
7707846100
MDR Report Key10513797
MDR Text Key207896792
Report Number1018233-2020-05791
Device Sequence Number1
Product Code OTP
Combination Product (y/n)N
Reporter Country CodeUS
PMA/PMN Number
K082571
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type Other
Reporter Occupation Non-Healthcare Professional
Type of Report Initial,Followup,Followup,Followup
Report Date 01/24/2024
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/10/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date08/30/2008
Device Catalogue Number486101
Device Lot NumberCVRI0022
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Device Age2 MO
Event Location Hospital
Date Manufacturer Received01/08/2024
Was Device Evaluated by Manufacturer? Device Not Returned to Manufacturer
Date Device Manufactured09/06/2007
Is the Device Single Use? Yes
Is This a Reprocessed and Reused Single-Use Device? No
Type of Device Usage Initial
Patient Sequence Number1
Treatment
BOSTON SCIENTIFIC OBTRYX.; UNK.
Patient Outcome(s) Required Intervention;
Patient Age60 YR
Patient SexFemale
Patient Weight58 KG
-
-