Model Number 1365-53-000
Device Problem Adverse Event Without Identified Device or Use Problem (2993)
Patient Problems Pain (1994); Discomfort (2330); Injury (2348); Test Result (2695); No Code Available (3191)
Event Date 01/05/2018
Event Type  Injury  
Manufacturer Narrative
Product complaint # (b)(4).Initial reporter occupation: lawyer.(b)(4).If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.
 
Event Description
Pinnacle claim submission form and medical records received.After review of the medical records the patient was revised due to pain, discomfort with elevated metal ions.Operative note reported abundant amount of capsular tissue was excised and some inferior bone.However, there were no lab result provided for the metal ions.Doi: (b)(6) 2006.Dor: (b)(6) 2018; left hip 2nd revision.
 
Manufacturer Narrative
Product complaint # (b)(4).Investigation summary: no device associated with this report was received for examination.The information received will be retained for potential series investigations if triggered by trend analysis, post market surveillance, or other events within the quality system.Depuy considers the investigation closed.Should additional information be received, the information will be reviewed and the investigation will be re-opened as necessary.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
ARTICULEZE M HEAD 36MM +8.5
Type of Device
ARTICULEZE HEAD (12/14 TAPER) : HIP METAL FEMORAL HEADS
Manufacturer (Section D)
DEPUY ORTHOPAEDICS INC US
700 orthopaedic drive
warsaw IN 46581 0988
MDR Report Key10574035
MDR Text Key208144896
Report Number1818910-2020-20729
Device Sequence Number1
Product Code LPH
UDI-Device Identifier10603295033950
UDI-Public10603295033950
Combination Product (y/n)N
PMA/PMN Number
K980513
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type consumer,other
Type of Report Initial,Followup
Report Date 09/11/2020
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received09/23/2020
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Expiration Date07/31/2011
Device Model Number1365-53-000
Device Catalogue Number136553000
Device Lot Number2203301
Was Device Available for Evaluation? No
Date Manufacturer Received10/27/2020
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Treatment
5.0MM DIA TPRD HD PER SCRW 55; 5.0MM DIA TPRD HD PER SCRW 55; CONTROL CABLE W/CABLE SLEEVE; CONTROL CABLE W/CABLE SLEEVE; CONTROL CABLE W/CABLE SLEEVE; CONTROL CABLE W/CABLE SLEEVE; PINNACLE DP REV ACET CUP 62MM; PINNACLE MTL INS NEUT36IDX56OD; SOL 21.0 BOW LT 8.0 12/14; 5.0MM DIA TPRD HD PER SCRW 55; 5.0MM DIA TPRD HD PER SCRW 55; CONTROL CABLE W/CABLE SLEEVE; CONTROL CABLE W/CABLE SLEEVE; CONTROL CABLE W/CABLE SLEEVE; CONTROL CABLE W/CABLE SLEEVE; PINNACLE DP REV ACET CUP 62MM; PINNACLE MTL INS NEUT36IDX56OD; SOL 21.0 BOW LT 8.0 12/14
Patient Outcome(s) Required Intervention;
Patient Age66 YR
Patient Weight120
-
-