Catalog Number 157105000 |
Device Problems
Degraded (1153); Device Dislodged or Dislocated (2923); Adverse Event Without Identified Device or Use Problem (2993)
|
Patient Problems
Fatigue (1849); Pain (1994); Test Result (2695); No Code Available (3191); Appropriate Clinical Signs, Symptoms, Conditions Term / Code Not Available (4581)
|
Event Date 09/27/2018 |
Event Type
Injury
|
Manufacturer Narrative
|
(b)(4).Initial reporter occupation: lawyer.If information is obtained that was not available for the initial medwatch, a follow-up medwatch will be filed as appropriate.Investigation summary = > no device associated with this report was received for examination.A worldwide lot specific complaint database search, or manufacturing record evaluation, was not possible as the required lot number was not provided.The information received will be retained for trend analysis, post market surveillance, or other events within the quality system.
|
|
Event Description
|
Asr litigation records received.Litigation alleges pain, suffering, fatigue, emotional distress and elevated chromium and cobalt level in the blood.Plaintiff is seeking compensation.Doi: (b)(6) 2007; dor: (b)(6) 2018 ; left hip.
|
|
Event Description
|
Revision notes stated that the head initially dissociated from the taper, and then the taper was knocked off the trunnion.Exposed surface appeared to be corroded.
|
|
Manufacturer Narrative
|
Product complaint # (b)(4).This report is being submitted pursuant to the provisions of 21 cfr, part 803.This report may be based on information which has not been investigated or verified prior to the required reporting date.This report does not reflect a conclusion by depuy synthes joint reconstruction, or its employees that the report constitutes an admission that the product, depuy synthes joint reconstruction, or its employees caused or contributed to the potential event described in this report.Udi (b)(4).H6 clinical code: appropriate term/ code not available (e2402) is used to capture injury (e20).If information is obtained that was not available for the initial report, a follow-up report will be filed as appropriate.
|
|
Manufacturer Narrative
|
Product complaint # (b)(4).Investigation summary : no device associated with this report was received for examination.A worldwide lot specific complaint database search, or manufacturing record evaluation, was not possible as the required lot number was not provided.The information received will be retained for trend analysis, post market surveillance, or other events within the quality system.Device history lot : the product investigation found no evidence suspecting an error in the manufacturing or material that would be a contributing factor in the reported allegation(s).A manufacturing records evaluation (mre) was not performed.
|
|