• Decrease font size
  • Return font size to normal
  • Increase font size
U.S. Department of Health and Human Services

MAUDE Adverse Event Report: GYRUS ACMI INC SHOCKPULSE-SE LITHOTRIPSY SYSTEM (REUSAB; LITHOTRIPTOR, ULTRASONIC

  • Print
  • Share
  • E-mail
-
Super Search Devices@FDA
510(k) | DeNovo | Registration & Listing | Adverse Events | Recalls | PMA | HDE | Classification | Standards
CFR Title 21 | Radiation-Emitting Products | X-Ray Assembler | Medsun Reports | CLIA | TPLC
 

GYRUS ACMI INC SHOCKPULSE-SE LITHOTRIPSY SYSTEM (REUSAB; LITHOTRIPTOR, ULTRASONIC Back to Search Results
Model Number SPL-SR
Device Problem Output Problem (3005)
Patient Problem No Patient Involvement (2645)
Event Date 09/15/2020
Event Type  malfunction  
Manufacturer Narrative
The subject device has not yet been received for evaluation.The cause of the issue cannot be determined at this time.If additional information becomes available this report will be supplemented accordingly.
 
Event Description
It was reported that during preparation for use for a lithotripsy procedure, the device exhibited error, probe error message illuminated in red on error, and probe error buttons.User tried two different handpiece however, the issue was not resolved.The intended procedure was completed by using a laser device.The serial number on the device used was not provided.No patient harm, or injury reported due to the event.No user injury reported.
 
Manufacturer Narrative
This supplemental report is being submitted to provide review of the device history records (dhr), unique device identifier (udi) number, device evaluation and investigation conclusion.The device was returned to olympus uk (united kingdom).Evaluation of the device, the reported issue was confirmed as the unit was found not to produce output due to faulty transducer receptacle.One leg with its screw was also missing.Device history records were reviewed and showed the product met all specifications upon release.The reported failure is a known phenomenon and is produced as a result of damage to the transducer receptacle.Damage to the receptacle is often incurred as a result of user error, often the user does not realize all connections are push/pull and instead the plug is twisted upon connection or removal.This action results in damage to the pins internal to the socket and may crack or damage the housing.As stated on the ifu (instruction for use) the user manual states: connect the transducer to the generator by pressing the plug straight in.Caution do not twist or turn the plug.Connect the transducer to the generator by aligning the key way of the transducer connector with the key way slot on the transducer receptacle on the front panel.Push straight in.Caution do not twist or turn the plug.Olympus will continue to monitor complaints for this device.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
SHOCKPULSE-SE LITHOTRIPSY SYSTEM (REUSAB
Type of Device
LITHOTRIPTOR, ULTRASONIC
Manufacturer (Section D)
GYRUS ACMI INC
136 turnpike road
southborough PA 01772
MDR Report Key10665260
MDR Text Key210912846
Report Number3011050570-2020-00100
Device Sequence Number1
Product Code FEO
Combination Product (y/n)N
PMA/PMN Number
K142428
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup
Report Date 01/25/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received10/12/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberSPL-SR
Was Device Available for Evaluation? Yes
Was the Report Sent to FDA? No
Date Manufacturer Received01/21/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-