Model Number WA22706S
Device Problem Break (1069)
Patient Problem Device Embedded In Tissue or Plaque (3165)
Event Date 11/27/2020
Event Type  malfunction  
Manufacturer Narrative
The device referenced in this report has not been returned to olympus for physical evaluation.The definitive cause of the customer's experience cannot be determined at this time.The investigation is ongoing.This report will be updated upon completion of the investigation or upon receipt of additional relevant information.
 
Event Description
It is reported during a cystoscopy and transurethral resection of the prostate (turp) using a hf-resection electrode (plasma loop) with a borrowed resectoscope, the first loop broke during the case and fell into the patient.They removed the first broken electrode.(reported in related complaint with patient identifier (b)(6)).A second loop was opened and upon starting to use the second electrode, it broke as well and fell into the patient.The doctor was not able to remove this loop fragment (this report).A third loop was opened, it partially broke, but did not fall into the patient (reported in related complaint with patient identifier (b)(6)).The user then pulled out their own resectoscope working element and opened a 4th loop.The procedure was then completed without any further difficulty.There was no other changes to the fluid, generator, or settings.The user could not verify if the borrowed working element was the exact same model cause as their resectoscope.The patient did not experience any adverse effects as a result of this occurrence and was discharged as planned.
 
Manufacturer Narrative
This report is being supplemented to provide additional information based on the legal manufacturer's investigation.A review of the device history record found no deviations that could have caused or contributed to the reported issue.Though the subject device was not returned for evaluation, based on the legal manufacturer's investigation, it is likely that excessive force in combination with anatomical or procedural complication during surgery had contributed to the breakage.
 
Manufacturer Narrative
This report is being updated to provide an investigation update performed after the physical evaluation of the first loop used in the procedure that was broken off and retrieved (reported in mw 9610773 - 2020 - 00301).New information is reported in h6 and h10.Updated investigation findings: physical evaluation of the plasma loop broken off in the procedure and retrieved reveals: the electrode shows a wire break where the loop has melted down to the fork insulation.There are melting points on the ceramic insulation tubes as well as clear traces of heat development on the insulation tubes.It is not reported that fragments of the loop were recovered from the body.However, the origin of the crystalline residue on the electrode fork is unclear.Updated investigation analysis conclusion: during the use of the second electrode, this loop also broke and could not be removed.The third loop also broke, but no part fell into the patient.The patient received standard, continuous, high-flow bladder irrigation for up to 24 hours after the turp procedure.This bladder irrigation probably flushed any remaining fragment of the loop out of the bladder.There is no known problem related to the event after the patient's discharge.Moreover, even if a fragment remained in the bladder, it is unlikely to cause a serious injury afterwards.It is concluded excessive force in combination with anatomical or procedural complication during surgery has likely contributed to the breakage.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
HF-RESECTION ELECTRODE "PLASMALOOP", LOOP, MEDIUM, 24 FR., 12-30, ESG TURIS
Type of Device
HF-RESECTION ELECTRODE "PLASMALOOP"
Manufacturer (Section D)
OLYMPUS WINTER & IBE GMBH
kuehnstrasse 61
hamburg, hamburg 22045
GM  22045
MDR Report Key11064849
MDR Text Key227362606
Report Number9610773-2020-00300
Device Sequence Number1
Product Code FAS
UDI-Device Identifier14042761085356
UDI-Public14042761085356
Combination Product (y/n)N
PMA/PMN Number
K171965
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,user f
Type of Report Initial,Followup,Followup
Report Date 08/30/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/23/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model NumberWA22706S
Device Catalogue NumberWA22706S
Device Lot Number1000061354
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Manufacturer Received08/12/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Age65 YR
Patient Weight84
-
-