Model Number TJF-Q180V
Device Problem Residue After Decontamination (2325)
Patient Problems No Patient Involvement (2645); No Clinical Signs, Symptoms or Conditions (4582)
Event Date 11/12/2020
Event Type  malfunction  
Manufacturer Narrative
The device in this report has not been investigated by the manufacturer yet.Therefore the exact cause of the reported has not been conclusively determined.This report will be supplemented once the investigation has been concluded.
 
Event Description
A technical service engineer of olympus medical systems (b)(4) private limited reported that foreign materials adhered to the distal end of the device.No patient was involved in this event.The device was inspected by olympus because the customer reported that the device failed a leakage testing due to a damage on the bending section after an endoscopy.There is no other information provided at this moment.This report will be supplemented if additional information is available.
 
Manufacturer Narrative
This supplemental report is being submitted to provide additional information.The subject device has not been returned to olympus medical systems corp.(omsc) for evaluation.The field service engineer (fse) of olympus informed that the user facility had conducted reprocessing according to our recommendation.The fse will arrange one more reprocessing training for the user facility.Omsc reviewed the manufacturing history (dhr) of the subject device and confirmed no irregularity.The exact cause of the reported phenomenon could not be conclusively determined.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
EVIS EXERA II DUODENOVIDEOSCOPE
Type of Device
DUODENOVIDEOSCOPE
Manufacturer (Section D)
OLYMPUS MEDICAL SYSTEMS CORP.
2951 ishikawa-cho
hachioji-shi, tokyo-to 192-8 507
JA  192-8507
MDR Report Key11092898
MDR Text Key225248860
Report Number8010047-2020-11115
Device Sequence Number1
Product Code FDT
UDI-Device Identifier04953170367311
UDI-Public04953170367311
Combination Product (y/n)N
PMA/PMN Number
K143153
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,distri
Type of Report Initial,Followup
Report Date 02/15/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received12/29/2020
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator No Information
Device Model NumberTJF-Q180V
Was Device Available for Evaluation? No
Was the Report Sent to FDA? No
Date Manufacturer Received02/04/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
-
-