ATRIUM MEDICAL CORPORATION FLIXENE GRAFTS W/GDS; PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER Back to Search Results
Model Number 25058
Device Problems Complete Blockage (1094); Adverse Event Without Identified Device or Use Problem (2993)
Patient Problem Embolism (1829)
Event Date 01/18/2021
Event Type  Injury  
Manufacturer Narrative
On completion of the investigation a follow up report will be submitted.
 
Event Description
Approximately 45 days after flixene was inserted, blood clots were formed in the veins of autogenous vascular which caused blockage.The patient returned to the emergency room of the hospital for revascularization.The blockage occurred again shortly after the revascularization.Thus, the patient returned to the hospital again.
 
Event Description
N/a.
 
Manufacturer Narrative
Based on the details of the complaint the patient formed a blood clot about 45 days after flixene graft was inserted, blood clots were formed in the veins of autogenous vascular graft which caused blockage.The patient returned to emergency room (er) of the hospital for revascularization.The blockage occurred again shortly after the revascularization.To obtain as much information as possible regarding this case multiple questions were asked to understand patient conditions.The information provided indicates the patient was not on any anti-coagulation medication and was being cannulated three times a week.The image that was provided shows that the blockage is occurring in the native vessel and not within the flixene graft.It is unknown why the patient has experienced blood clot formations within their native vasculature however; adverse reactions or complications that can occur with the use of any vascular graft include but are not limited to thrombus formation and stenosis.This is captured in the instructions for use (ifu) provided with the flixene graft in the adverse reactions section.Blood clots or thrombus formation can occur and there is a section in the ifu called "thrombectomy" which states that in the event that an incision needs to be made to the advanta or flixene graft (e.G.For the purpose of providing an access site for declotting the distal anastomosis) post implantation, the following is recommended: ¿ if and when a longitudinal incision is made for a thrombectomy, it is recommended to place a stay stitch at each end of the longitudinal incision prior to balloon catheter use.¿ a horizontal mattress suture technique should be used for closure of the incision site of the graft.¿ do not apply excessive tension on the implanted advanta or flixene eptfe graft during inflated balloon catheter withdrawal.Over inflation of an embolectomy, balloon or use of an inappropriate sized catheter may cause damage to the graft and anastomosis.¿ extreme care must be exercised with the use of all mechanical water jet thrombectomy and mechanical rotary brush devices to not disrupt or damage the advanta or flixene eptfe graft material, prior vascular access holes and/or suture line.There was no product returned therefore an evaluation of the reported device could not be conducted.The review of the dhr did not identify any issues in regards to the performance of the graft.The details provided indicate that the patient conditions and operative technique played a role in the formation of the blood clots.The image provided also indicated that the clots were not within the flixene graft but proximal and distal of the implant.Based on the provided complaint details, the device history record review and response from the physician, the investigation could not conclude or confirm that the flixene graft was the cause of the blood clot formation.
 
Event Description
N/a.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
FLIXENE GRAFTS W/GDS
Type of Device
PROSTHESIS, VASCULAR GRAFT, OF 6MM AND GREATER DIAMETER
Manufacturer (Section D)
ATRIUM MEDICAL CORPORATION
40 continental blvd
merrimack NH
MDR Report Key11256702
MDR Text Key229570962
Report Number3011175548-2021-00111
Device Sequence Number1
Product Code DSY
UDI-Device Identifier00650862250589
UDI-Public00650862250589
Combination Product (y/n)N
PMA/PMN Number
K071923
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type company representative,foreig
Type of Report Initial,Followup,Followup
Report Date 01/31/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received01/31/2021
Is this an Adverse Event Report? Yes
Is this a Product Problem Report? No
Device Operator Health Professional
Device Model Number25058
Device Catalogue Number25058
Device Lot Number437736
Was Device Available for Evaluation? No
Date Manufacturer Received05/23/2021
Is This a Reprocessed and Reused Single-Use Device? No
Patient Sequence Number1
Patient Outcome(s) Required Intervention;
Patient Age73 YR
-
-