Model Number 22042
Device Problem Inappropriate or Unexpected Reset (2959)
Patient Problem No Consequences Or Impact To Patient (2199)
Event Date 01/14/2021
Event Type  malfunction  
Manufacturer Narrative
Attempts have been made to obtain the product.The product has not been returned to masimo to allow an analysis to be performed.If the product is returned for evaluation or new information is obtained, a follow up report will be submitted.
 
Event Description
The customer reported the unit won't stay on.No patient impact or consequences were reported.
 
Manufacturer Narrative
Additional manufacturing narrative: other, other text: the returned device was evaluated.Visual inspection found no external damage or defects.The unit powered on and off using ac power and dc power, but the unit restarts continuously as soon as it is powered on and doesn't remain on.Internal inspection found contamination damages on the cable connector from the system board to ui board.There was also contamination damages on the ui board, led display circuit board, and the cable connecting the ui board to the keypad.A service history record review reveals that this unit was in the field for over three (3) years with no previous reported issues related to this reported event.
 
Event Description
The customer reported the unit won't stay on.No patient impact or consequences were reported.
 
Search Alerts/Recalls

  New Search  |  Submit an Adverse Event Report

Brand Name
RAD-8, HORIZONTAL
Type of Device
OXIMETER
Manufacturer (Section D)
MASIMO - 52 DISCOVERY
52 discovery
irvine CA 92618
MDR Report Key11350898
MDR Text Key233060391
Report Number3011353843-2021-00042
Device Sequence Number1
Product Code DQA
UDI-Device Identifier00843997005647
UDI-Public00843997005647
Combination Product (y/n)N
PMA/PMN Number
K053269
Number of Events Reported1
Summary Report (Y/N)N
Report Source Manufacturer
Source Type distributor,health profession
Remedial Action Other
Type of Report Initial,Followup
Report Date 01/28/2021
1 Device was Involved in the Event
1 Patient was Involved in the Event
Date FDA Received02/19/2021
Is this an Adverse Event Report? No
Is this a Product Problem Report? Yes
Device Operator Health Professional
Device Model Number22042
Device Catalogue Number9190
Was Device Available for Evaluation? Device Returned to Manufacturer
Date Returned to Manufacturer02/18/2021
Was the Report Sent to FDA? No
Date Manufacturer Received03/10/2021
Is This a Reprocessed and Reused Single-Use Device? No